142
-
TROUBLESHOOTING
CHECKING THE HYDRAULIC FLOW AT RATED PRESSURE
3. Determine the circuit relief valve pressure and oil flow.
NOTE:
First, warm the carrier’s hydraulic system to operating temperature.
Measure the flow and pressure with the loading flow meter (t36). Adjust the load
valve (f1) to zero restriction
(fully open)
. Set the engine throttle to the maximum
(full)
position. Energize Material Processor to close switch.
Slowly turn the loading valve knob (fm1) clockwise and record the pressure and flow at
regular pressure intervals (pr) on graph paper. Record pressure on one axis of the
graph and flow (fl) on the other. This is the circuit flow chart. Refer to the
“MODEL
SPECIFICATIONS”
section of this manual for the correct flow at 1000 psi (70 bar).
fl
FLOW (gpm)
pr
PRESSURE (psi)