134
-
TROUBLESHOOTING
MATERIAL PROCESSOR SEQUENCE, RELIEF VALVE AND
CARRIER RELIEF VALVE SETTINGS
MODEL SERIAL NO.
P1
P2
P3
PROCESSOR
PROCESSOR
MINIMUM CARRIER
SEQUENCE
RELIEF VALVE
RELIEF VALVE
VALVE SETTING
SETTING
SETTING
psi
(bar)
psi
(bar)
psi
(bar)
M20
ALL
2,950
(205)
3,625
(250)
3,825
(265)
M28
ALL
2,950
(205)
3,625
(250)
3,825
(265)
M38
ALL
2,950
(205)
3,625
(250)
3,825
(265)
RELIEF VALVE LOCATION
The Material Processor relief valve cartridges, close (c17) and open (c18) are located
in the relief blocks (bs24) that are bolted to the rotary joint assembly (BN).