140
-
TROUBLESHOOTING
TEST PROCEDURE
SLOW CYLINDER SPEED
PROBLEM
CAUSE
CHECK
REMEDY
Operating Pressure
is less than 3,625
psi (
250 bar
).)
Carrier hydraulic
circuit relief valve.
Measure the carrier
circuit relief valve with
the pressure to close
shut-off valve in the
"OFF"
position
Adjust or replace the
carrier circuit relief
valve. The setting
for the relief valve
must be 200 psi (
14
bar
), minimum,
above the Material
Processor operating
pressure.
Material Processor
relief valves
Measure the relief
valves with the shut-
off valves on the
carrier in the
"ON"
position. Check
pressure with the
jaws fully open and
fully closed.
Setting should be
3,625 psi (
250 bar
).
Check relief
cartridges for
tightness.
Tighten the relief
valve cartridges.
Check relief
cartridges for mis-
adjustment.
Reset to 3,625 psi
(
250 bar
). If unable
to adjust, replace
the cartridge.
Check the o-rings
and backup rings of
the relief valve
cartridges.
Replace the o-rings
and backup rings of
both relief valve
cartridges.
Booster sequence
valve cartridge.
Observe sequence
valve operation. (See
"PRESSURE
INTENSIFIER
SEQUENCE AND
RELIEF VALVE
ACTUATION"
)
Replace the
sequence valve
cartridge. (
NOTE:
The sequence valve
cartridge is not
adjustable.
)
Check the o-rings
and backup rings of
the sequence valve
cartridge.
Replace the o-rings
and backup rings of
the sequence valve
cartridge.
Summary of Contents for M20C
Page 23: ... 23 SERIAL NUMBER LOCATION M20 ...
Page 24: ... 24 SERIAL NUMBER LOCATION M28 ...
Page 25: ... 25 SERIAL NUMBER LOCATION M38 ...
Page 149: ... 149 WARRANTY STATEMENTS ...