29
-
NITROGEN GAS PRESSURE
The nitrogen gas pressure must be measured with no preload on the tool. Remove
the tool; or position the hammer with the tool fully extended against the tool retaining
pin. The hammer must not be resting vertical on the tool. The gas pressure in the
hammer will vary according to the gas temperature.
PREFERRED METHOD
The preferred method to measure or charge the nitrogen gas pressure is with the
hydraulic system temperature stabilized after 1 to 2 hours of running and with a
system oil temperature of 140° to 180°F (60° to 80°C).
ALTERNATE METHOD
The nitrogen gas pressure can be measured or charged at ambient temperature
(cold), before operating the hammer. It is recommended the pressure be verified at
operating temperature.
DO NOT OVERCHARGE THE HAMMER!
Exceeding the gas pre-charge specifications can result in
damaging hammer components. The NPK WARRANTY does not cover failures
resulting from exceeding the specified nitrogen gas pressure.
NITROGEN GAS PRE-CHARGE
MODEL
AT AMBIENT TEMPERATURE
(cold, before operating)
psi (bar)
(plus 0, minus 25)
AT OPERATING TEMPERATURE
psi (bar)
(plus 0, minus 25)
GH06
350 (24)
405 (28)
GH07
350 (24)
405 (28)
GH1
350 (24)
405 (28)
GH2/GHS2
350 (24)
405 (28)
GH3
350 (24)
405 (28)
GH4
375 (26)
435 (30)
GH6
390 (27)
450 (31)
GAS CHARGING KIT / PART NO. 7300588
ALL NPK HYDRAULIC HAMMERS are furnished with the following gas charging kit.
In addition, a nitrogen tank and pressure regulator valve (not furnished with the
hammer) are required. These can be obtained from your local welding supply
house. An optional regulator valve is available from NPK.
g1. CHARGE ADAPTER (PART NO. 30604040)
g3. PLUG (PART NO. 30102050)
g4. HOSE (PART NO. 20118010)
g5. CHARGING KIT BOX (PART NO. 35001030)
g6. CAP (PART NO. 30100500)
g7. OPTIONAL REGULATOR VALVE (PART NO.
21101050)