8
-
HAMMER SPECIFICATIONS
IMPACT TOOL
ENERGY DIA
WORKING
HAMMER
MODEL
CLASS
FREQUENCY
WORKING
WEIGHT
MOUNTING
STYLE
LENGTH
ft lb
bpm
lbs (Kg)
in (mm)
in (mm)
GH06
150
480 – 1200
500 (225) Skid Steer
1.7 (42) 12.2 (311)
235 (107)
Excavator
GH07
200
500 – 1200
550 (250) Skid Steer
1.9 (47) 13.1 (333)
270 (125)
Excavator
GH1
350
550 – 1100
750 (340) Skid Steer
2.2 (57) 13.6 (346)
450 (205)
Excavator
GH2/GHS2
500
500 – 1300
800 (365) Skid Steer
2.6 (66) 14.4 (367)
525 (240)
Excavator
GH3
750
500 – 1150
1075 (490) Skid Steer
3.0 (76) 16.1 (408)
800 (365)
Excavator
GH4
1300
400 – 1050
1250 (570)
Excavator
3.4 (86) 18.0 (458)
GH6
2000
500 – 800
2150 (980)
Excavator
4.2 (106) 20.0 (500)
GAS CHARGE
PRESSURE
5
OIL FLOW
HYDRAULIC
OPERATING
PRESSURE
1
CIRCUIT
RELIEF
minimum
2
Cold
3
Hot
4
HAMMER
MODEL
gpm (L/min)
psi (bar)
psi (bar)
psi (bar)
psi (bar)
GH06
2.5 – 7 (10 - 25)
1650 (115)
2150 (150)
350 (24)
405 (28)
GH07
4 – 9 (15 - 35)
1500 (105)
2000 (140)
350 (24)
405 (28)
GH1
7 – 13 (25 - 50)
1750 (120)
2250 (155)
350 (24)
405 (28)
GH2/GHS2
7 – 17 (25 - 65)
2250 (160)
2750 (190)
350 (24)
405 (28)
GH3
12 – 26 (45 - 100)
1900 (130)
2400 (165)
350 (24)
405 (28)
GH4
13 – 32 (50 - 120)
2200 (150)
2700 (185)
375 (26)
435 (30)
GH6
24 – 40 (90 - 150)
2400 (165)
2900 (200)
390 (27)
450 (31)
*Specifications are subject to change without notice.
NOTES:
1. Hydraulic operating pressure maximum is inlet pressure at the hammer with the oil
at operating temperature and with the gas charge set at the hot operating pressure.
See CHECKING THE HYDRAULIC PRESSURES section in this manual.
2. Circuit relief pressure is at least 500 psi (35 bar) above hammer operating pressure.
3. Cold gas charge is the initial set with the hammer at ambient temperature.
4. Hot gas charge is checked after 1 to 2 hours of running and with a system oil
temperature of 140
°
to 180
°
F (60
°
to 80
°
C). This is the preferred check.
5. Pressures listed are maximum. Use tolerance of minus 25 psi (2 bar).