ACO403 BT
25
EN
10 Re-pressing
Re-pressing is always necessary if a pressing operation has not been fully completed. Check the
system supplier's instructions to ascertain whether re-pressing is permitted. If it is permitted, please
note the following differences from the initial pressing operation that must be complied with.
WARNING!
Risk of injury from breaking claws on the adaptor jaw and damaged pins
on the press collar
Holding the press device incorrectly and changing its position before and during re-
pressing means that the claws can no longer grip the pins properly.
The tips of the claws may press directly on the pins, causing the claws and pins to
break and fragments to fly off.
Therefore:
– After positioning on the press collar, press the jaw levers on the adaptor jaw
together as far as possible using the grip. (Fig. 12)
– Make sure that the claws of the adaptor jaw always grip the press collar pins
throughout the re-pressing operation. (Fig. 11)
11 Cleaning, maintenance and repair
CAUTION!
Risk of injury during cleaning or repair work from inadvertently pressing
the On switch.
Therefore:
– Comply with the safety instructions and always remove the battery before
performing cleaning, servicing or repair work.
Service addresses
Novopress GmbH & Co. KG
Scharnhorststr. 1
41460 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting Novopress or at
www.novopress.de.
Maintenance intervals
Maintenance and repair work may only be carried out by Novopress or the authorised NOVOPRESS
specialist workshops.
Information!
The next maintenance service is indicated on the press device and the press collar.
This maintenance service must be performed at least once a year. If more than 2,500
pressing operations are performed in a year, maintenance service must be performed
after these 2,500 operations at the latest.
An LED indicates that the maintenance interval has been reached 100 pressing
operations in advance (see Section 8.1 Meaning of the LED display).
The red and green LED flash slowly and simultaneously to indicate that 500 pressing
operations are left before reaching the maximum number of operations. The device
must be taken to maintenance service within these 500 pressing operations, otherwise
it automatically blocks itself after these 500 pressing operations.
•
Summary of Contents for ACO403 BT
Page 4: ...ACO403 BT ...
Page 18: ...ACO403 BT 14 DE ...
Page 32: ...ACO403 BT 28 EN ...
Page 46: ...ACO403 BT 42 FR ...
Page 60: ...ACO403 BT 56 IT ...
Page 74: ...ACO403 BT 70 ES ...
Page 88: ...ACO403 BT 84 NL ...
Page 102: ...ACO403 BT 98 SV ...
Page 116: ...ACO403 BT 112 FI ...
Page 130: ...ACO403 BT 126 NO ...
Page 144: ...ACO403 BT 140 PT ...
Page 158: ...ACO403 BT 154 DA ...
Page 172: ...ACO403 BT 168 EL ...
Page 186: ...ACO403 BT 182 RU ...
Page 200: ...ACO403 BT 196 PL ...