ACO403 BT
24
EN
Information!
To ensure that the press collars function correctly, the sliding segments must be free to
move.
The sliding segments are always pressed back automatically into the correct starting
position by springs.
Therefore:
– Ensure that marking lines (M) on shells (C) are aligned with the edges of the sliding
segments (D) when the press collar is in starting position. (Fig. 5)
– If this is not the case, have the press collars repaired.
1. Check that the nominal size of the press fitting matches the nominal size of the press collar.
Information!
Comply with the system supplier’s instructions when positioning the press collar on the
press fitting.
CAUTION!
There is a risk that the press collar will break if it is positioned incorrectly
If the press collar is positioned incorrectly on the fitting the press collar may become
damaged.
Therefore:
– The line (A) must be at the same height of the edge (B).
(Fig. 7)
– If this is not the case, remove the press collar again and reposition it
2. Swivel the outer shells of the press collar outwards as far as possible and then position the press
collar on the press fitting.
3. Close the press collar. (Fig. 6)
4. Open the adaptor jaw fully using the grip.
WARNING!
Risk of injury from ejected fragments
If the adaptor jaw is positioned on the press collar incorrectly, the adaptor jaw and the
press collar may break.
Therefore
– Claws (21) of the adaptor jaw must grip pins (22) of the press collar.
(Fig. 11, 12 + 13)
5. Position the adaptor jaw on the press collar as follows.
Push claws (21) of the adaptor jaw as far as possible into grooves (24) in the press collar.
(Fig. 10)
6. Close the adaptor jaw using the grip.
Information!
Ensure there is no gap between the segments of the press collar when the
pressing operation is complete.
Information!
If the press device is switched off, briefly press the start button (1) to activate the
press device. Press the start button again to start the pressing operation.
7. In order to start the process, press the start button and hold it down.
8. After the pressing operation has been completed, open the adaptor jaw using the grip and detach
it from the press collar.
9. Open the press collar and remove it.
Summary of Contents for ACO403 BT
Page 4: ...ACO403 BT ...
Page 18: ...ACO403 BT 14 DE ...
Page 32: ...ACO403 BT 28 EN ...
Page 46: ...ACO403 BT 42 FR ...
Page 60: ...ACO403 BT 56 IT ...
Page 74: ...ACO403 BT 70 ES ...
Page 88: ...ACO403 BT 84 NL ...
Page 102: ...ACO403 BT 98 SV ...
Page 116: ...ACO403 BT 112 FI ...
Page 130: ...ACO403 BT 126 NO ...
Page 144: ...ACO403 BT 140 PT ...
Page 158: ...ACO403 BT 154 DA ...
Page 172: ...ACO403 BT 168 EL ...
Page 186: ...ACO403 BT 182 RU ...
Page 200: ...ACO403 BT 196 PL ...