8.2 Starting position of the press collar (Fig. 5)
Information!
To ensure that the press collars function correctly, the sliding segments must be free to
move.
The sliding segments are always pressed back automatically into the correct starting
position by springs.
Therefore:
– Ensure that marking lines (M) on shells (C) are aligned with the edges of the sliding
segments (D) when the press collar is in starting position. (Fig. 5)
– If this is not the case, have the press collars repaired.
The press collar must be positioned in the way shown (oval shape) before it is placed on a fitting. After
the press collar has been opened and removed from a fitting, the press collar must again be
positioned in the way shown.
8.3 Closing the collar (Fig. 6 + 7)
•
By pressing the outer end of the shell gently, the shell moves inwards. (Fig. 6)
CAUTION!
There is a risk that the press collar will break if it is positioned incorrectly
If the press collar is positioned incorrectly on the fitting the press collar may become
damaged.
Therefore:
– The line (A) must be at the same height of the edge (B).
(Fig. 7)
– If this is not the case, remove the press collar again and reposition it.
•
The line (A) must be at the same height of the edge (B) when the press collar is positioned
correctly. (Fig. 7)
8.4 Opening the collar (Fig. 8 + 9)
To open the press collar, the two outer shells can be swivelled away from the pipe, either individually
or together, as described below.
First try the process with one hand before you try it with both hands together.
If you just open one side first and then the other you must hold the press collar tightly when opening
the second side so that it does not fall off.
•
To open the press collar the following 2 steps must be carried out. (Fig. 8)
o
Press lever (15) at the position marked in the direction of the pipe and hold it
there.
o
Grip shell (16) at the position marked from below and swivel it away from the
pipe.
•
Once a certain point has been reached the shell automatically moves to its final
position and makes an audible click.
•
By pulling the two outer shells (16) apart, open the press collar far enough to remove
it from the press fitting. (Fig. 9)
Summary of Contents for ACO403 BT
Page 4: ...ACO403 BT ...
Page 18: ...ACO403 BT 14 DE ...
Page 32: ...ACO403 BT 28 EN ...
Page 46: ...ACO403 BT 42 FR ...
Page 60: ...ACO403 BT 56 IT ...
Page 74: ...ACO403 BT 70 ES ...
Page 88: ...ACO403 BT 84 NL ...
Page 102: ...ACO403 BT 98 SV ...
Page 116: ...ACO403 BT 112 FI ...
Page 130: ...ACO403 BT 126 NO ...
Page 144: ...ACO403 BT 140 PT ...
Page 158: ...ACO403 BT 154 DA ...
Page 172: ...ACO403 BT 168 EL ...
Page 186: ...ACO403 BT 182 RU ...
Page 200: ...ACO403 BT 196 PL ...