Programming Overview
1x
3-9
30-
37
Exit
Enter
Menu
Item
Selection
Entry
Menu-
point
No.
FU- settings
Operator selection
Motor Novo Speed Flex
1
SE 14.21
4
SE 6.115
5
SI 14.80
6
SI 20.90
7
SI 30.46
8
SI 5.250
9
Exit menu
- -
SE 9.20
2
SE 9.24
3
no motor selected
0*
SE 3,5.120
10
TD 2.60.180
11
SI 35.60
12
TD 2.65.142 actual version (DES 20:1)
13
14
SI 35.30
15
SI 65.24
16
TD 2.65.142 older version (DES 15:1)
79
Open speed
Close speed
Soft run
Acceleration time open
Braking time open
Acceleration time close
Braking time close
Soft run distance
Motor brake
Menu 70
Menu 71
Menu 72
Menu 73
Menu 74
Menu 75
Menu 76
Menu 77
Menu 78
Menu 79
* 14 DES 15:1
Speed
70
72
74
73
Speed
71
72
76
75
77
77
78
78
Drive select
* Factory defaults
GB
Recommended adjustments
60
12
10
10
25
25
25
12
1
13*
30
15
6
10
10
10
15
13
1
10
45
25
3
7
20
15
15
13
1
12
50
25
6
30
30
30
10
13
1
6
75
50
3
15
20
15
15
13
1
8
40
25
6
6
20
20
10
13
0
0
25
12
3
30
30
30
30
13
1
5
Speed Flex
MotovarioSI 6.1
15
SI 14.80
SI 30.46 SI 3,5.120SI 35.60Speed
Thermo
TD 65.142
50
25
6
7
10
10
10
4
0
7
SI 20.90
TD 2.75.120
17