Programming Overview
1x
3-9
30-
37
Exit
Enter
Menu
Item
* Factory defaults
Interlock circuit
Door state for A800 traffic lights control
Wipe impulse ELTACO
Hand transmitter on / off (menu 62)
5 minutes garage light
2 minutes garage light
Door open signal
Door closed signal
Status relay X5
3
2
6
5
4
3
1
0*
45
Menu-
point
Door open signal
Door closed signal
Status relay X6
1*
0
46
No.
4
Extended door settings
Selection
Entry
Warning lamp on open and close move (0 - 10 secs.)
15 - 25
210 secs. ... 22,5 min. (in 30 secs. increments)
35 secs. ... 180 secs. (in 5 secs. increments)
1 sec. ... 30 secs. (in 1 sec. increments)
0 Sek.
Hold-open phase in seconds
Partial reversing
Full reversing
Response of safety edge
AR - automatic closing
Impulse OPEN / Impulse CLOSE
Impulse OPEN / Dead man CLOSE
Dead man OPEN / Dead man CLOSE
Membrane key function
0... 100mm higher
0... 50mm deeper
Adjustment pre-limit switch safety edge
4-wire photocell LS5, Reflection photocell
2-wire photocell LS2
without photocell
Selecting the photocell
Measuring value display (press 5 sec.)
Selecting the closing edge
0... 80mm higher
0... 80mm deeper
Fine adjustment of top end-of-travel position
Setting the door's half-open position
Setting the door's bottom end-of-travel position
Change of direction (press for 5 sec.)
Setting the door's top end-of-travel position
Selection
61 - 99
31 - 60
1 - 30
0*
1
0*
3
2*
1
0
25 - 99
25 - 0
25*
2
1
0*
No.
3
Basic door settings
Extended door settings
50 - 99
50 - 0
50*
Entry
40
37
36
33
32
31
30
Menu-
point
0... 80mm higher
0... 80mm deeper
Fine adjustment of bottom end-of-travel position
50 - 99
50 - 0
50*
34
41
- -
35
4
2
Motor starting time
1
0*
49
5
6
3
Photocell Ls5, frame fitted reflection photocell
4
44
4
Exit menu
- -
Exit menu
25 min / 60%
25 min / 20%
25 min / 35%
No limit
10 min / 35%
25 min / 30%
25 min / 60%
Pressure wave edge DW with testing
Electrical safety edge 8K2
Optical closing edge OSE
2
1*
0
Electric safety edge 8K2 with slack rope switch
3
Photocell LS2, frame fitted reflection photocell
3
grid
(SG14)
Light
with testing
5
Wireless closing edge, RadioBand
4
Shortening the hold-open time during AR service
Without shortening the hold-open time
Light barrier response
1
0*
38
Door state for A800 traffic lights control
2
Warning lamp on close move (0-10 secs. advance warning)
4 - 14
GB