04/13 Rev. 1.12-02
USER / SERVICE MANUAL
Mounting/Setup
LA-TO / LA-TO XL
Settings
19
Settings
Parameter settings
ALX 92x
The following parameters control the operation of the
ALX 92x and LA -TO. You must set these parameters
before using the unit for the first time:
For more information on how to set the parameters,
refer to the service manual under
.
ALS 20x/30x, ALX 73x(LMA)
The following parameters control the operation of the
ALS 20x, ALS 30x and ALX 73x with LA -TO. You must
set these parameters before using the unit for the first
time:
For more information on how to set the parameters, re-
fer to service manual of the respective machine type.
Parameter
Setting
APPLICATOR PARA > Applicator type
„LA-TO Timed“
“LA-TO Sensor“
APPLIKATOR PARA > Apply mode
Depends on application
APPLIKATOR PARA > Dwell time
Only required for „LA-TO Timed“
Depends on application
[Tab. 3] Settings for firmware versions up to 6.37 (AI: 1.23)
Parameter
Setting
LABEL SETUP > Dispense speed
Depends on application. Operating the
unit
without
APSF is recommended.
SIGNAL SCHNITTST > Schnittst. Mode
„Applik. Signale“
SIGNAL SCHNITTST >APPLIK. SIGNALE > Applicator type
a
SIGNAL SCHNITTST >AI BOARD SIGNAL > Applicator type
b
a) Applicator controlled by standard signal interface.
b) Applicator controlled by optional applicator interface.
„LA-TO Timed“ (time controlled)
“LA-TO Sensor“ (sensor controlled)
SIGNAL SCHNITTST >APPLIK. SIGNALE > Apply mode
SIGNAL SCHNITTST >AI BOARD SIGNAL > Apply mode
Depends on application
SIGNAL SCHNITTST >APPLIK. SIGNALE > Dwell time
SIGNAL SCHNITTST >AI BOARD SIGNAL > Dwell time
Applies only to time controlled LA-TO
Depends on application
[Tab. 4] Settings for firmware version 1.34 (ALS) respectively 1.36
(ALX) (AI: 1.23).