Sensor adjustment
Adjust the home position
The upper limit stop of the piston rod in the pneumatic
cylinder is referred to as the “home position”. This posi-
tion must be reliably detected by the home position
sensor.
Tool
Small screwdriver (0.6x4 mm)
Functionality check of the home position sensor:
1. Unplug the compressed air line.
2. Slowly push the vacuum plate upwards. While do-
ing this, check that the home position sensor de-
tects the pressure plate when the plate is
approximately 2 mm below the upper limit stop.
Applicators controlled by applicator interface:
The sensor is active when the status LED „Home“
at the interface lights up.
3. If necessary, loosen the clamping bolt [29A] and
move the home position sensor onto the pneumatic
cylinder.
4. Refasten the home position sensor using the
clamping bolt.
WARNING!
Injury hazard by unintentionally triggered
applicator.
Unplug the compressed air line before
starting the adjustment.
[29] Adjust the home position