USER / SERVICE MANUAL
Mounting/Setup
LA-TO / LA-TO XL
For your safety
9
Connecting an interlocking guard
The illustrations in this chapter show exemplary a LA -TO at an ALS 20x RH labeller
(pictured without cables and hoses). The following instructions apply equally to all
other LA -TO versions.
According to the EC machinery directive, the LA -TO is a
partly completed machine
.
In order that the completed machine matches the health and safety requirements of
the machinery directive, LA -TO
must
be safeguarded against access by an appropri-
ate safeguarding device
1
(see ]).
Connect the interlock switch D] of the safeguarding device to the connector A] de-
livered with the applicator (see E]).
Plug the connector to the switch box B].
Operation of the LA -TO without the described safeguarding device shall be re-
garded as abnormal use. Avery Dennison assumes no liability for damage due to ab-
normal use of the printer.
[3] Connecting the interlock switch (A) of the safeguarding device (or an emergency-stop switch) to a
LA -TO (at an ALS 20x).
[4] Plug that comes with the LA -TO for connecting an interlock switch to the
LA -TO (article number: A102076).
1) Movable interlocking guard according to EN ISO 12100-1, 3.25.4