04/13 Rev. 1.12-02
USER / SERVICE MANUAL
Mounting/Setup
LA-TO / LA-TO XL
Assembly
14
Mounting to ALS 20x
Tools
4/6 mm hex socket screwdrivers
Assembly
1. Switch-off the ALS 20x.
Mark the lateral position of the dispensing edge
(material zero-line), before disassembling it.
2. Unscrew 1 screw [13A] and take off the dispensing
edge [13B].
3. Unscrew 2 screws [13C] and remove the lower
4. Push the LA -TO onto the holding rods and fasten it
there using the locking screws [13E].
5. Remount the dispensing edge.
Position the dispensing edge as marked before.
6. Connect the cable to LA -TO and ALS 20x.
Connection to standard signal interface [11A]
(article no.: A7074)
Connection to applicator interface [12A]
(article no.: A8752)
7. Connect the interlock circuit of the protective guard
to the LA -TO [9B].
See chapter
Connecting an interlocking guard
Connecting an interlock circuit is mandatory.
The LA -TO must not and cannot be operated with-
out.
8. Install the pressure regulator.
See chapter
Installing the pressure regulator
9. Connect the compressed air supply.
See chapter
Connecting the compressed air hose
10. Switch-on the ALS 20x.
11. Make setting in the parameter menu.
See chapter
12. Adjust the LA -TO.
See chapter
[13] Mounting the LA -TO to an ALS 20x
[14] Connecting to an ALS 20x (standard signal interface).
[15] Connecting to an ALS 20x (optional applicator interface).