Chapter Four: Installation and Operation
© 2018 Cutting Edge Optronics, Inc.
24
Patara I and II Laser User Manual
eDrive Setup
Input Power
Use only power cords suitable for the driver. Use a power source that delivers
voltage in the range of 90 VAC (RMS) to 240 VAC (RMS) and 47 Hz to 63 Hz.
Power switching is performed automatically (i.e., there are no configuration
switches to set for high or low voltage ranging).
Table 4-4
provides
recommended fuse selection for each voltage range.
Table 4-4. Recommended Fuse Ratings
AC Input
Frequency
Fuse Ratings
(F1, F2)
120 V / 15 A
47-63 Hz
15 A
240 V / 7 A
47-63 Hz
8 A
Mounting
The front panel of the eDrive is designed with four holes to mount into an EIA-
310D-compliant rack. If this option is used, the eDrive’s weight requires extra
side supports. If the eDrive is to be used on a desktop or table top, it is
recommended that the eDrive be equipped with feet to prevent the driver from
marring the surface when it is moved. The eDrive must be secured.
Clearance
Adequate clearance should be allowed on the front, sides, and rear of the eDrive
for access to connections and components. The front and rear vents of the eDrive
must be a minimum of 24 inches (61 cm) away from walls or vertical surfaces so
air flow is not restricted.