DVRN960 User
’s Manual
29
3.6.3
Alert Notification Setup
This function allows users to send alert notifications to the CMS software
which had been installed to users
’ computer. For further setup instruction at
the CMS side
, please refer to the CMS user’s manual.
Alert Notification Setup
Alert Configuration Set
Alert Notification
Alert IP
Alert Port
Alive Interval
1
OFF
0.0.0.0
9999
120 Sec
3.6.3.1
Alert Configuration Set
<Alert Configuration Set> provides 3 combinations of Alert Notification, IP,
Port, and Interval.
3.6.3.2
Alert Notification
4 options are included in this item: <OFF>, <Event>, <Alive>, and <Both>.
<
OFF
>: The Alert Notification is turned off.
<
Event
>: When the alarm is triggered, the DVR will send an alert message to
the CMS.
<
Alive
>: The DVR will send an alive message to the CMS every
N
second
just to show that the connection between the DVR and CMS is
active. The time interval
N
can be adjusted in <Alive Interval>.
<
Both
>: This enables the DVR to send both Event and Alive alert messages
to the CMS.
3.6.3.3
Alert IP
The Alert IP must match the IP address of the computer installed the CMS.
3.6.3.4
Alert Port
The ports for DVR and the CMS Alert
MUST
be the same.
3.6.3.5
Alert Interval
Users can define the time interval (1 to 255 seconds) between each alive
message. This item will not be available if <Alert Notification> is set to <OFF>
or <Event>.
Summary of Contents for DVRN960 Series
Page 2: ...DVRN960 User s Manual 1 ...