Page 54 of 64
Implementation and operation
553-2681-100 Standard 5.00 August 1996
Testing
The tests in
, which follows, are conducted when the CAS feature
is installed at a Remote site that will be served by a CAS attendant. These
procedures can also be used as a guide to locating a fault in the feature.
describe tests that verify that the CAS attendant can
receive and handle calls from any site arranged for the CAS feature.
Procedure 1
Testing the CAS feature at a Remote site
1
Verify that all CAS data is correct. See feature implementation.
2
Verify that the Release Link Trunks (RLT) are installed and enabled.
3
Verify that the Tone and Digit Switches (TDS) are installed and
enabled.
4
From any telephone, dial the DN of an RLT. If the RLT is busy, a busy
tone is heard. If the RLT is idle, the following events occur:
—
A Ringback (RGB) tone is heard.
—
When the CAS attendant answers, the Ringback tone stops and
a voice path is established.
Verify that a two-way conversation can be carried out. Release the
call.
5
Repeat step 4 for each RLT.
6
From any telephone, dial the DN for the local attendant. This call is
presented to the local attendant as a normal dial “0” call.
Testing the CAS feature at a Remote site
Testing the CAS feature at the CAS Main attendant
Answering an incoming call from a Remote site while at
the CAS Main
Extending a call to an idle telephone at a Remote site
Extending a call to a busy telephone with Camp-On