Ordering information and system engineering rules
8-23
Planning Guide NT6Q92MA Standard Rel 1.0 Iss 1 September 2006
Procedure 8-1 (continued)
Ordering OME6130 chassis, circuit packs, and software
Action
Step
Action
Note:
Use a photocopy of
for this procedure. All line
number references are to this table unless noted otherwise.
1
Determine the number of 10/100BT Ethernet Private Line (EPL) services that
are required, record the number in
. If no 10/100BT EPL services are
required, enter ‘none’ on
.
Note:
A maximum of 32 10/100BT EPL ports can be provisioned per
OME6130 shelf (8 ports for each 8x10/100BT L1 tributary circuit pack).
2
Determine the number of 8x10/100BT L1 tributary circuit pack that are
required. Divide the number recorded on
by 8 and record the round up
integer value on
. Enter ‘none’ if no 8x10/100BT L1 tributary circuit pack
is required.
3
Determine the number of GE EPL services that are required, record the
number in
. If no GE EPL services are required, enter ‘none’ on
Note:
A maximum of 8 GE EPL ports can be provisioned per OME6130 shelf
(2 ports for each 2xGE L1 tributary circuit pack).
4
Determine the number of 2xGE L1 tributary circuit pack that are required.
Divide the number recorded on
by 2 and record the round up integer
value on
. Enter ‘none’ if no 2xGE L1 tributary circuit pack is required.
5
Determine the number of E1/DS1 services that are required, record the
number in
. If no E1/DS1 services are required, enter ‘none’ on
Note:
A maximum of 112 E1/DS1 ports can be provisioned per OME6130
shelf (28 ports for each 28xE1/DS1 tributary circuit pack).
6
Determine the number of 28xE1/DS1 tributary circuit pack that are required.
Divide the number recorded on
by 28 and record the round up integer
value on
. Enter ‘none’ if no 28xE1/DS1 tributary circuit pack is
required.
7
Determine the number of E3/DS3 services that are required, record the
number in
. If no E3/DS3 services are required, enter ‘none’ on
Note:
A maximum of 12 E3/DS3 ports can be provisioned per OME6130
shelf (3 ports for each 3xE3/DS3 tributary circuit pack).
8
Determine the number of 3xE3/DS3 tributary circuit pack that are required.
Divide the number recorded on
by 3 and record the round up integer
value on
. Enter ‘none’ if no 3xE3/DS3 tributary circuit pack is
required.