7-4
Technical specifications
Optical Multiservice Edge 6130 NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Refer to
for a list of power cables assemblies available
and the
Installation
,
Commissioning and Testing Procedures
, 323-1855-201
for details on installing and connecting power to an OME6130 shelf.
Table 7-4
Power consumption for each circuit pack at -54 V dc
Circuit pack
Typical
(W)
8x10/100BT L1
7.6
2xGE L1
8
3xE3/DS3
8
28xE1/DS1
7.2
2x155M
8
Table 7-5
Power consumption for each SFP at -54 V dc
STM-1/4 and GE SFP modules
Typical
(W)
STM-1 SR0 (multimode)
0.7
STM-1/4 S1.1/4.1
0.7
STM-1/4 L1.1/4.1
0.7
STM-1/4 L1.2/4.2 XCT
0.7
STM-1/4 CWDM
0.7
STM-1 (100Base) Bidirectional at 1310nm
0.7
STM-1 (100Base) Bidirectional at 1550nm
0.7
STM-1e (electrical)
0.7
GE SX
0.7
GE LX
0.7
Table 7-6
Recommended feeders
Configuration
Feeders per shelf
OME6130 chassis with
DC PSU
A feed (
6
A) and redundant B feed (
6
A)
Summary of Contents for Optical Multiservice Edge 6130