![Nortel Meridian 1 Mini-Carrier Remote Description, Installation, And Maintenance Download Page 96](http://html1.mh-extra.com/html/nortel/meridian-1-mini-carrier-remote/meridian-1-mini-carrier-remote_description-installation-and-maintenance_1706402096.webp)
Page 96 of 150
Installation and configuration
P0914209
Standard 3.00
April 2000
Figure 47
SET ESAM: TRUNK PARAMETERS: BALANCE IMPEDANCE screen
c
Termination Impedance -
This variation of the SET ESAM
command allows the user to change the termination impedance of
the trunk from its default of 600 ohms. Its display is similar
to Figure 48.
Figure 48
SET ESAM: TRUNK PARAMETERS: TEMINATION IMPEDANCE screen:
d
Dialing Speed-
This variation of the SET ESAM command
allows the user to change the dialing speed of the trunk, from its
default of “DIGITONE.” Its display is similar to Figure 49.
Enter Trunk Balance Impedance
1 - Complex, 2 - 600 ohms, <cr> - No Change
Trunk 0 Existing Balance - Complex New Balance - 2 Balance Now - 600 Ohms
Trunk Setup Menu for Trunk 1:
1 - Trunk Type
2 - Balance Impedance
3 - Termination Impedance
4 - Dialing Speed
9 - Return To Main Menu
Enter Trunk Termination Impedance
1 - 600 ohms, 2 -900 ohms, 3 - 1200 ohms, <cr> - No Change
Trunk 0 Existing Termination - Complex New Termination - Termination Unchanged
Trunk Setup Menu for Trunk 1:
1 - Trunk Type
2 - Balance Impedance
3 - Termination Impedance
4 - Dialing Speed
9 - Return To Main Menu