![Nortel Meridian 1 Mini-Carrier Remote Description, Installation, And Maintenance Download Page 46](http://html1.mh-extra.com/html/nortel/meridian-1-mini-carrier-remote/meridian-1-mini-carrier-remote_description-installation-and-maintenance_1706402046.webp)
Page 46 of 150
Description
P0914209
Standard 3.00
April 2000
No damage or malfunction occurs at up to +/- 20 kV of direct discharge. An
indirect discharge of up to +/- 20 kV does not result in malfunction of the
system (to adjacent equipment or connected cabling).
Safety requirements
•
Underwriters Laboratory (UL): The MCR circuit packs comply with and
are recognized under UL 1950, third edition.
•
Canadian Standards Association (CSA): The MCR circuit packs comply
with and are certified under CSA C22.2, No. 225 and No. 950-95.