Installation and configuration
Page 89 of 150
Mini-Carrier Remote
Description, Installation, and Maintenance
Figure 32
SET ALARM (S A) screen
SET CONFIG (S C)
This command equips or unequips the T1 carriers. Its display is similar to
Figure 33.
Figure 33
SET CONFIG (S C) screen
SET NAME (S N)
This command sets the name of the near end and remote sites. Its display is
similar to Figure 34.
Figure 34
SET NAME (S N) screen
SET ESAM (S E)
This command configures the settings for ESAM protection. Its display is
similar to Figure 35.
MCR::>s a
Alarm 1 Threshold: Min - E-3 Max - E-9
[Current Value - 5] - 5
Threshold Duration (in seconds) Min - 1 Max - 2148
[Current Value - 10] - 10
Alarm 2 Threshold: Min - E-3 Max - E-9
[Current Value - 4] - 4
Threshold Duration (in seconds) Min - 1 Max - 218
[Current Value - 10] - 10
Frame Slip Threshold (Min - 1 Max - 255)
[Current Value - 100] - 100
Frame Slip Threshold Duration (in Minutes) Min - 1 Max - 1440
[Current Value - 2] - 2
MCR::>
MCR::>s c
Equip Carrier 0 (YES or NO) Y
Equip Carrier 1 (YES or NO) Y
MCR::>
MCR::>s n
Change Near End Site Name (YES or NO) N