Mini-Carrier Remote
Description, Installation, and Maintenance
122
Appendix A: Man-Machine Interface
(MMI) commands
The appendix provides a list and brief explanation of the man-machine
interface (MMI) commands available to users through the RS-232 terminal
located at the local site.
Table 20
MMI commands
Command
Description
A D
Alarm disable. Disables all local and remote carrier alarms. Maint. LED lit.
A E
Alarm enable. Enables all local and remote carrier alarms.
C A
Clear alarm. Clears all local and remote carrier alarms.
C A L
Clear alarm log. Clears near-end alarm log.
C A L D
Clear alarm log distant. Clears distant-end alarm log.
C E
Clear error. Clears near-end error counters for all carriers.
C E D
Clear error distant. Clears distant-end error counters for all carriers.
C M
Clear memory. Restores all configuration settings on the near-end card to their
original default values.
C M D
Clear memory distant. Restores all configuration settings on the distant-end
card to their original default values.
D A
Display alarm log. Displays near-end alarm log.
D A D
Display alarm log distant. Displays distant-end alarm log.
—continued—