Digital Telephone IP Adapter Installation and Administration Guide
107
June 2005
Changing configuration settings using Configuration Manager
RLC Connection configuration field descriptions
Field
Description
Unit ID
The RLC’s non-configurable unit ID of 254.
RLC Port Number
Enter the RLC voice port number designated for the
Digital Telephone IP Adapter unit on the RLC Remote
connection configuration property sheet.
The default is 0.
IP Connection
Click on the
Enable
option button, if you want to route
calls over your IP network.
Click on the
Disable
option button, if you do not want
to route calls over your IP network.
The default is Disable.
IP Connection: IP Address
Enter the RLC’s IP address. The Digital Telephone IP
Adapter unit uses this IP address to connect to the RLC
over the IP network.
IP Connection: IP
Signaling
Click on the
Permanent
option button to configure this
port’s IP connection to be up at all times.
Click on the
On Demand
option button to configure
this port’s IP connection to be up only when needed.
The default is Permanent.
Refer to “Deployment” on page 40 for help in determining
which setting to configure.
PSTN Connection
This setting does not apply to Digital Telephone IP
Adapters.
PSTN Connection: PSTN
Number to Connect to
RLC
This setting does not apply to Digital Telephone IP
Adapters.