302693-B Rev 00
4-65
Troubleshooting
InsertionInterval
Variable Name:
docsIfCmtsInsertionInterval
Set/Get Response/Status:
Number (TimeTicks)
Description:
The amount of time to elapse between each
broadcast station maintenance grant. Broad-
cast station maintenance grants are used to
allow new cable modems to join the network.
Zero indicates that a vendor-specific algo-
rithm is used instead of a fixed time. Maxi-
mum amount of time permitted by the
specification is two seconds.
REFERENCE
Data Over Cable Radio Frequency Interface
Specification, Ranging Interval.
InvitedRangingAttempts
Variable Name:
docsIfCmtsInvitedRangingAttempts
Set/Get Response/Status:
Number
Description:
The maximum number of attempts to make
on invitations for ranging requests. A value of
zero means the system should attempt to
range forever.