4-44
302693-B Rev 00
CMTS 1000 Installation Manual V1.2
Id
Variable Name:
docsIfUpChannelId
Set/Get Response/Status:
Number
Description:
The CMTS identification of the upstream
channel.
Frequency
Variable Name:
docsIfUpChannelFrequency
Set/Get Response/Status:
Number (Hertz)
Description:
The center of the frequency band associated
with this upstream channel. This object
returns 0 if the frequency is undefined or
unknown. Minimum permitted upstream fre-
quency is 5,000,000 Hz.
Width
Variable Name:
docsIfUpChannelWidth
Set/Get Response/Status:
Number (Hertz)
Description:
The bandwidth of this upstream channel. This
object returns 0 if the channel width is unde-
fined or unknown. Minimum permitted chan-
nel width is 160,000 Hz.