Connecting the server to power
Standard 1.06
62
CallPilot
In rack-mount server installations, ensure the CallPilot server
chassis and equipment racks are isolated from other foreign sources
of ground. Acceptable isolation methods include: isolation pads,
grommeted washers, chassis side-rail strips, and nonconducting
washers.
In rack-mount server installations where other equipment is also
installed in the same rack, ensure that all equipment derives ground
from the same service panel as CallPilot and the switch.