30
MG1E-056F1AAM1
MODEL NAME/
HEATING INPUT
MOTOR
SPEED
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
MG1E-056F1AAM1
56,000 BTU/Hr
5 - High*
1,524
1,491
1,458
1,421
1,385
1,348
1,308
1,270
4 - Alternate
1,199
1,160
1,122
1,080
1,037
993
946
899
3 - Med-High
1,013
972
928
876
829
780
728
675
2 - Med-Low
890
843
790
735
683
615
566
510
1 - Low
798
749
695
629
442
369
MG1E-070F1AAM1
MODEL NAME/
HEATING INPUT
MOTOR
SPEED
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
MG1E-070F1AAM1
70,000 BTU/Hr
5 - High*
1,573
1,541
1,511
1,479
1,452
1,419
1,388
1,358
4 - Alternate
1,387
1,353
1,321
1,289
1,254
1,216
1,183
1,148
3 - Med-High
1,212
1,178
1,148
1,114
1,079
1,036
1,005
964
2 - Med-Low
931
886
836
782
732
670
620
565
1 - Low
640
599
562
513
476
425
MG1E-077F1AAM1
MODEL NAME/
HEATING INPUT
MOTOR
SPEED
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
MG1E-077F1AAM1
77,000 BTU/Hr
5 - High*
1,573
1,541
1,511
1,479
1,452
1,419
1,388
1,358
4 - Alternate
1,333
1,300
1,268
1,236
1,201
1,162
1,129
1,093
3 - Med-High
1,212
1,178
1,148
1,114
1,079
1,036
1,005
964
2 - Med-Low
996
960
924
885
848
814
772
734
1 - Low
683
642
599
540
498
451
386
MG1E-090F1AAM1
MODEL NAME/
HEATING INPUT
MOTOR
SPEED
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
MG1E-085F1AAM1
85,000 BTU/Hr
5 - High*
1,590
1,555
1,521
1,493
1,458
1,426
1,397
1,371
4 - Med-High
1,337
1,306
1,274
1,243
1,210
1,182
1,142
1,104
3 - Med-Low
1,188
1,154
1,119
1,091
1,054
1,023
984
941
2 - Alternate
1,015
978
956
917
871
834
792
740
1 - Low
779
742
698
654
617
564
516
472
NOTES:
1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
2. Data is shown without filter.
3. The “*” denotes the factory heat and cool setting. If a different motor speed is needed, the appropiate wire from the “HEAT” or “COOL”
tap on the control board must be connected to the desired Tap (1-5) at the motor.
Table 16. Cooling Airflow (CFM)
Summary of Contents for MG1 Series
Page 31: ...31...