Operation
4-9
Part 1604858-01
E
2013 Nordson Corporation
NOTE:
Do not immerse electrode assemblies in solvent. They cannot be
disassembled; cleaning solution and rinse water will remain inside the
assembly.
1. Fill an ultrasonic cleaner with BetaSolv or an equivalent emulsion
cleaning solution at room temperature. Do not heat the cleaning
solution.
2. Remove the parts to be cleaned. Remove the O-rings. Blow off the
parts with low-pressure compressed air.
NOTE:
Do not allow O-rings to come in contact with the cleaning solution.
3. Place the parts in the ultrasonic cleaner and run the cleaner until all
parts are clean and free of impact fusion.
4. Rinse all parts in clean water and dry before re-assembly. Inspect the
O-rings and replace any that are damaged.
NOTE:
Do not use sharp or hard tools that will scratch or gouge the smooth
surfaces of powder contact parts. Scratches will cause impact fusion.