System Setup
3-8
Part 1604858-01
E
2013 Nordson Corporation
Remote Connections for Multi-Gun Controllers
Remote Trigger
Bring the trigger cable into the enclosure through one of the AUX strain
reliefs and connect it to the J4 terminals on the main control board(s). To
trigger the gun(s) the T1
−
T8 trigger circuits must be pulled low (sinking).
These circuits operate on 10 mA
±
1
.
Conveyor Interlock
The conveyor interlock uses the red and orange leads in the power cable.
The interlock is factory wired for 240V, but can be changed to 120V at the
J3 terminal block on the trigger distribution board.
NOTE:
If the conveyor interlock is not used, the keyswitch must be set to
Bypass in order to operate the guns.
GND
T8
COM
T7
T6
T5
T4
T3
T2
T1
J6
J4
J3
J1
J2
J5
ENCORE LT
TRIGGER DISTRIBUTION
PCA
COM
COM
COM
COM
COM
CON-5
CON-4
CON-3
CON-2
CON-1
LO-5
LO-4
LO-3
LO-2
LO-1
T8
T7
T6
T5
T4
T3
T2
T1
BLACK
BLUE
RED
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
WHITE “H”
WHITE “G”
WHITE “F”
WHITE “E”
WHITE “D”
WHITE “C”
WHITE “B”
WHITE “A”
120V
240V
AC COM
CGRND
COM
LOCKOUT
COM
BYP
ASS
COM
TRIGGER
ORANGE
RED
CONVEYOR
INTERLOCK
BLACK
RED
BLACK
BLUE
WHITE
BLACK
AXIS CONTROLLER
GUN CONTROL BOARDS
POWER CORD
REMOTE TRIGGER SIGNALS
T1 = GUN #1
Figure 3-7
Multi-Gun Controller
−
Remote Trigger/Conveyor Interlock Connections
Summary of Contents for Encore LT Automatic
Page 4: ...Change Record ii Part 1604858 01 E 2013 Nordson Corporation...
Page 8: ...Table of Contents vi Part 1604858 01 E 2013 Nordson Corporation...
Page 12: ...Safety 1 4 Part 1604858 01 E 2013 Nordson Corporation...
Page 20: ...Description 2 8 Part 1604858 01 E 2013 Nordson Corporation...
Page 34: ...System Setup 3 14 Part 1604858 01 E 2013 Nordson Corporation...
Page 44: ...Operation 4 10 Part 1604858 01 E 2013 Nordson Corporation...
Page 63: ...Wiring Diagrams 7 1 Part 1604858 01 E 2013 Nordson Corporation Section 7 Wiring Diagrams...
Page 64: ...Wiring Diagrams 7 2 Part 1604858 01 E 2013 Nordson Corporation...