Troubleshooting
6-39
Part 1107600_03
2014
Nordson Corporation
+
−
Fault LED is illuminated >
F2 fault exists >
Tank key LED is illuminated >
No hot melt was recently added to the
tank
T.2.3
?
+
−
Is the resistance correct for
the tank heaters (2) and
the pump heater (1)? Refer
to
Heater Specifications
in
Section 8 for resistance
values.
+
−
Is the voltage across the
downstream side of fuses
F1 and F2 on the main
board 180-265 VAC?
Are the tank and pump
TRIACS functioning
properly?
?
Contact Nordson for
technical assistance.
+
−
Are the tank and manifold
RTDs functioning properly?
Replace the tank or the
pump heater.
Refer to Section 7,
Parts
.
Check/correct house
voltage.
Replace the main board.
P/N 1078624
Replace the malfunctioning
RTD.
Tank ‐ P/N 1031234
Pump ‐ P/N 1031233
Stop.
+
−
Does replacing fuses F1
and F2 on the main board
and then resetting the
melter clear the fault?
P/N 1028329
Replace the main board.
P/N 1078624
+
−
Are any of the indicators
DS2, DS3, or DS7 on the
main board illuminated?
+
−
Is the power indicator for
the affected hose/gun
illuminated?
Check the operation of the
power relay or the
thermostat.
Summary of Contents for AltaBlueA4TP
Page 8: ...Table of Contents vi Part 1107600_03 2014 Nordson Corporation...
Page 20: ...Safety 1 12 2014 Nordson Corporation Issued 10 11...
Page 31: ...Installation 3 3 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 39: ...Installation 3 11 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 46: ...Installation 3 18 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 60: ...Installation 3 32 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 64: ...Installation 3 36 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 74: ...Installation 3 46 Part 1107600_03 2014 Nordson Corporation...
Page 108: ...Operation 4 34 Part 1107600_03 2014 Nordson Corporation...
Page 122: ...Maintenance 5 14 Part 1107600_03 2014 Nordson Corporation...
Page 150: ...Troubleshooting 6 28 Part 1107600_03 2014 Nordson Corporation...
Page 152: ...Troubleshooting 6 30 Part 1107600_03 2014 Nordson Corporation...
Page 154: ...Troubleshooting 6 32 Part 1107600_03 2014 Nordson Corporation...
Page 156: ...Troubleshooting 6 34 Part 1107600_03 2014 Nordson Corporation...
Page 158: ...Troubleshooting 6 36 Part 1107600_03 2014 Nordson Corporation...
Page 160: ...Troubleshooting 6 38 Part 1107600_03 2014 Nordson Corporation...
Page 162: ...Troubleshooting 6 40 Part 1107600_03 2014 Nordson Corporation...
Page 164: ...Troubleshooting 6 42 Part 1107600_03 2014 Nordson Corporation...
Page 166: ...Troubleshooting 6 44 Part 1107600_03 2014 Nordson Corporation...
Page 168: ...Troubleshooting 6 46 Part 1107600_03 2014 Nordson Corporation...
Page 170: ...Troubleshooting 6 48 Part 1107600_03 2014 Nordson Corporation...
Page 199: ...Parts 7 21 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 216: ...Parts 7 38 Part 1107600_03 2014 Nordson Corporation...
Page 221: ...Technical Data 8 5 Part 1107600_03 2014 Nordson Corporation Figure 8 3 Wiring diagram 1 of 12...
Page 222: ...Technical Data 8 6 Part 1107600_03 2014 Nordson Corporation Figure 8 4 Wiring diagram 2 of 12...
Page 223: ...Technical Data 8 7 Part 1107600_03 2014 Nordson Corporation Figure 8 5 Wiring diagram 3 of 12...
Page 224: ...Technical Data 8 8 Part 1107600_03 2014 Nordson Corporation Figure 8 6 Wiring diagram 4 of 12...
Page 225: ...Technical Data 8 9 Part 1107600_03 2014 Nordson Corporation Figure 8 7 Wiring diagram 5 of 12...
Page 226: ...Technical Data 8 10 Part 1107600_03 2014 Nordson Corporation Figure 8 8 Wiring diagram 6 of 12...
Page 227: ...Technical Data 8 11 Part 1107600_03 2014 Nordson Corporation Figure 8 9 Wiring diagram 7 of 12...
Page 236: ...Calculating Melter Power Requirements A 4 Part 1107600_03 2014 Nordson Corporation...
Page 274: ...Melter Communications C 12 Part 1107600_03 2014 Nordson Corporation...
Page 276: ......