Troubleshooting
6-33
Part 1107600_03
2014
Nordson Corporation
Fault LED is illuminated
T.2
?
+
−
Is the tank key LED
illuminated?
Confirm that the RTD has
failed.
+
−
Go to
T.2.1
+
−
Are all of the gun‐to‐hose
and hose‐to‐melter
electrical cordsets securely
connected?
Does the fault reoccur if
you move the faulting
hose/gun pair to a known
good hose/gun connector?
Replace the hose or
replace the gun RTD.
Refer to the hose or gun
manual.
Go to
T.2.2
Secure the electrical
connectors and then press
the reset key.
Contact Nordson for
technical assistance.
Record the fault codes
indicated in both the left
and right displays and then
contact Nordson for
technical assistance.
+
−
Is an F1 (RTD) fault
indicated in the right
display?
+
−
Is an F2
(undertemperature) fault
indicated in the right
display?
+
−
Is an F3 (overtemperature)
fault indicated in the right
display?
+
Is an F4 fault indicated in
the right display?
Summary of Contents for AltaBlueA4TP
Page 8: ...Table of Contents vi Part 1107600_03 2014 Nordson Corporation...
Page 20: ...Safety 1 12 2014 Nordson Corporation Issued 10 11...
Page 31: ...Installation 3 3 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 39: ...Installation 3 11 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 46: ...Installation 3 18 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 60: ...Installation 3 32 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 64: ...Installation 3 36 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 74: ...Installation 3 46 Part 1107600_03 2014 Nordson Corporation...
Page 108: ...Operation 4 34 Part 1107600_03 2014 Nordson Corporation...
Page 122: ...Maintenance 5 14 Part 1107600_03 2014 Nordson Corporation...
Page 150: ...Troubleshooting 6 28 Part 1107600_03 2014 Nordson Corporation...
Page 152: ...Troubleshooting 6 30 Part 1107600_03 2014 Nordson Corporation...
Page 154: ...Troubleshooting 6 32 Part 1107600_03 2014 Nordson Corporation...
Page 156: ...Troubleshooting 6 34 Part 1107600_03 2014 Nordson Corporation...
Page 158: ...Troubleshooting 6 36 Part 1107600_03 2014 Nordson Corporation...
Page 160: ...Troubleshooting 6 38 Part 1107600_03 2014 Nordson Corporation...
Page 162: ...Troubleshooting 6 40 Part 1107600_03 2014 Nordson Corporation...
Page 164: ...Troubleshooting 6 42 Part 1107600_03 2014 Nordson Corporation...
Page 166: ...Troubleshooting 6 44 Part 1107600_03 2014 Nordson Corporation...
Page 168: ...Troubleshooting 6 46 Part 1107600_03 2014 Nordson Corporation...
Page 170: ...Troubleshooting 6 48 Part 1107600_03 2014 Nordson Corporation...
Page 199: ...Parts 7 21 Part 1107600_03 2014 Nordson Corporation This page intentionally left blank...
Page 216: ...Parts 7 38 Part 1107600_03 2014 Nordson Corporation...
Page 221: ...Technical Data 8 5 Part 1107600_03 2014 Nordson Corporation Figure 8 3 Wiring diagram 1 of 12...
Page 222: ...Technical Data 8 6 Part 1107600_03 2014 Nordson Corporation Figure 8 4 Wiring diagram 2 of 12...
Page 223: ...Technical Data 8 7 Part 1107600_03 2014 Nordson Corporation Figure 8 5 Wiring diagram 3 of 12...
Page 224: ...Technical Data 8 8 Part 1107600_03 2014 Nordson Corporation Figure 8 6 Wiring diagram 4 of 12...
Page 225: ...Technical Data 8 9 Part 1107600_03 2014 Nordson Corporation Figure 8 7 Wiring diagram 5 of 12...
Page 226: ...Technical Data 8 10 Part 1107600_03 2014 Nordson Corporation Figure 8 8 Wiring diagram 6 of 12...
Page 227: ...Technical Data 8 11 Part 1107600_03 2014 Nordson Corporation Figure 8 9 Wiring diagram 7 of 12...
Page 236: ...Calculating Melter Power Requirements A 4 Part 1107600_03 2014 Nordson Corporation...
Page 274: ...Melter Communications C 12 Part 1107600_03 2014 Nordson Corporation...
Page 276: ......