Operation
B 3-20
E
1998 Nordson Corporation
All rights reserved
303 779B
Issued 11/98
Manual 12-44
1. Access the library from the Auto Start-Up window by selecting the
LIBRARY button.
1244049A
2. Select the desired profile for auto start-up and close the Library
window. The desired profile will appear in the Program line at the
bottom of the Auto Start-Up window.
3. Select the desired day for auto start-up to occur for this profile. A
prompt will ask for the desired time of day to start the profile.
4. If desired, select Test Cycle from the the Auto Start-Up window to
perform a test cycle.
NOTE: Refer to
Test Cycle in this section for more information.
NOTE: A test cycle will last for approximately 45 minutes.
It is a good idea to program an auto start-up every day before the shift
starts. This pre-starts the oven on a profile and warms the oven before
production begins.
Before each shutdown cycle, the oven will show the next auto start-up
profile; this is a safety feature to ensure that the auto start-up is known
at shutdown.