11
5 Installation
The lamps are provided with threaded inserts on the bottom for the purpose of
mounting (see drawings in the appendix). Damage to the source of radiation may
occur if the permissible maximum values for mounting the lamps are exceeded.
Please note that the light source must be grounded if it is mounted or integrated in
a system using the fastening threads.
The lamp is connected to the liquid cooling system using the appropriate
connections and its functionality and seals are checked. In conclusion, it is
connected to the power source (Phoenix Contact 5-pin plug) and the DB15
interface for transferring data between SPS and the lamp.
Prior to initial operation of lamp, the proper attachment of all connections must be
inspected.
CAUTION!
Attention:
Do not operate the lamp without coolant.
Summary of Contents for BlueCure FL
Page 2: ...2...
Page 20: ...20 A Appendix A 1 Drawing of the BLUE CURE FL 8 0W 125X20 WC 395...