14
5.2 Power Supply Connection
The BlueCure lamp is connected with the power supply via a respective cable.
A 5-pin plug from Phoenix Contact is used for the connection (Type: PC5/5-STF1-7,62).
Connect the power supply cable of the lamp to the power supply according to the
instructions provided by the manufacturer of the power supply.
CAUTION!
Attention:
Do not plug in or disconnect the plug while under voltage. For this
purpose, turn the power supply off first.
V+ V- PE V- V+
Pin Function
Signal Level
Remark
V+ Input voltage
+47 to +49 V DC
+48 V DC input to the power supply of the lamp; cable color: red
V- Reference mass 0 V DC
Grounding for +48 V DC power supply of the lamp; cable color: black
PE Grounding (PE)
0 V DC
Cable color: green or green-yellow
V- Reference mass 0 V DC
Grounding for +48 V DC power supply of the lamp; cable color: black
V+ IInput voltage
+47 to +49 V DC
+48 V DC input to the power supply of the lamp; cable color: red
Summary of Contents for BlueCure FL