Classification of hazards:

The classification describes the potential risks that could occur depending on the
purpose of the application and the length of irradiation.  The risks must be
assessed and classified depending on the use of the UV LED light source.

The measurement distance for the classification of hazards is set at 200 mm
according to IEC 62471.

The risks groups defined in IEC 62471:

Risk-free

means that, based on this standard, there is no health hazard through

irradiation.

Risk Group 1

– Low risk

Does not pose an irradiation hazard under normal performance and use.

Risk Group 2

– Medium risk

No hazard based on the natural human reaction to a very intense glare or
generation of heat.

Risk Group 3

– High risk

Can be hazardous even in the case of brief exposure to irradiation.

CAUTION! 

Attention: 

The BlueCure lamp emits UV and brief visible light with an intense glare.
Never look at the UV light source without UV protective glasses.

Spectral distribution

Summary of Contents for BlueCure FL

Page 1: ...ure FL Please read this user manual carefully before initial operation Electronic pdf files of EFD manuals are also available at www nordsonefd com IMPORTANT Save this Sheet Forward to Maintenance or...

Page 2: ...2...

Page 3: ...nd Inspection 9 3 Functionality 9 4 Technical Specifications 10 5 Installation 11 16 5 1 SPS Connection 12 13 5 2 Power Supply Connection 14 5 3 Possible Connection Scenarios 15 16 6 On Off Control 16...

Page 4: ...azards DANGER This symbol indicates a direct hazard to the life and health of persons WARNING This symbol indicates a potential hazard to the life and health of persons CAUTION This symbol indicates a...

Page 5: ...gh intensity UV LED emitting devices for industrial applications To achieve short hardening times of the UV hardened materials intense UV radiation is necessary The standard CEI IEC 62471 describes th...

Page 6: ...d in IEC 62471 Risk free means that based on this standard there is no health hazard through irradiation Risk Group 1 Low risk Does not pose an irradiation hazard under normal performance and use Risk...

Page 7: ...in a distance 1 5 meters from the light source in order to protect eyes and skin Eye protection must be provided for work in the area within a distance of 1 5 to 3 meters from the point of the LED whe...

Page 8: ...subject to the EU Guidelines of the Chemicals Directive REACH Furthermore with regard to the planned candidate list of substances of very high concern SVHC issued on October 10 2008 Nordson EFD decla...

Page 9: ...e UV intensity correlates to that of a mercury vapor lamp with frequent electrical power consumption The BlueCure lamps are comprised of closely arranged semi conductor light emitting diodes that are...

Page 10: ...POWER AC 48V 32 0A http www meanwell com search rsp 1500 rsp 1500 spec pdf RSP 1500 48 Operational temperature 10 C to 40 C Humidity maximum of 80 rel humidity non condensing at 30 C Area of use Below...

Page 11: ...if it is mounted or integrated in a system using the fastening threads The lamp is connected to the liquid cooling system using the appropriate connections and its functionality and seals are checked...

Page 12: ...regarding the use of the output under 7 Intensity of the Radiation must also be complied with 6 Output 5 V DC 5 V DC The reference voltage is only intended for the operation of the lamp Improper use...

Page 13: ...utputs Pin 5 and 11 are not short circuit proof and may carry a maximum of 5 mA If multiple light sources are used together simultaneously the following pins can be looped through Pin 2 Input amp outp...

Page 14: ...in or disconnect the plug while under voltage For this purpose turn the power supply off first V V PE V V Pin Function Signal Level Remark V Input voltage 47 to 49 V DC 48 V DC input to the power sup...

Page 15: ...ensity from 20 to 100 No monitoring of errors and temperature Temperature monitoring via an external voltmeter No emergency shut off functionality S1 On off lamp T1 Power supply S1 On off lamp V1 exte...

Page 16: ...prevent heat from building Even if the surface of the lamp does not heat up high temperatures may develop in the area surrounding the lamp e g every material in the direct proximity for which there is...

Page 17: ...on Because the coolant extensively cools the cooling element of the lamp in certain operating conditions for expelling heat condensation may form in the lamp behind the glass of the light emitting wi...

Page 18: ...r cleaning the lamps 1 Run a solution consisting of vinegar and decalcified water Mixing ratio 1 1 n weight through the lamp for 15 minutes 2 In the next step run a pure vinegar solution through in th...

Page 19: ...ergency shut off functionality Bridge between pin 7 and grounding pin 14 Lamp output Bridge between pin 2 and pin 6 SLM error Check the wiring of the DB15 connection see 5 1 SPS Connection for this If...

Page 20: ...20 A Appendix A 1 Drawing of the BLUE CURE FL 8 0W 125X20 WC 395...

Page 21: ...21...

Page 22: ...Y Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship but not against damage caused by misuse abrasion corrosion negligence accide...

Reviews: