background image

19

10 Troubleshooting

Symptom

Component

Potential Cause and Remedy

The lamp does
not emit any
light

Power supply

- Check whether all cables are connected to the power

supply properly

- For this, follow the respective instructions of the power

supply manufacturer 

- Check whether the power supply is plugged in
- Check whether the voltage from the power supply to the

source of radiation is +48 V DC

Temperature fault

If the lamp displayed a temperature fault, no light will be
emitted until the lamp has reached a safe operating
temperature.  (see also:  Water-cooling below)

SPS control

See 5.1 ‘SPS Connection’ for troubleshooting the interface
DB15.  It is possible to test-run the lamp without SPS.  Turn
on the lamp with full intensity with the following bridges to
the DB15 interface:
- Turn on the lamp with a low signal:  Bridge between pin 4

and pin 10

- Emergency shut-off functionality:  Bridge between pin 7 and

grounding pin 14

- Lamp output:  Bridge between pin 2 and pin 6 

SLM error

- Check the wiring of the DB15 connection; see 5.1 ‘SPS

Connection’ for this.

- If the outlet pin 11 from the DB15 is applied to the ground

(0 to +0.4 V DC), then it is possible that an internal fuse
was set off.  For further information, contact Nordson EFD.

Temperature
increase of the
lamp by more
than 15°C

Water-cooling

- Check for the proper coolant through-flow
- Check the coolant temperature at the coolant inlet of the

lamp (m20 °C)

- If the lamp briefly (< 5 minutes) displayed a temperature

fault, check whether the temperature of the lamp is less
than +40 °C.  To determine the internal temperature of the
lamp, you will need a voltmeter.  Measure on pin 15
against the ground (+2 V = +20 °C). 

Film on the
inside of the
glass window 
of the lamp

Water-cooling

Check the environmental conditions of the light source for
potential signs of condensation.  The film could be formed by
the collection of condensation on the inside of the lamp.

Summary of Contents for BlueCure FL

Page 1: ...ure FL Please read this user manual carefully before initial operation Electronic pdf files of EFD manuals are also available at www nordsonefd com IMPORTANT Save this Sheet Forward to Maintenance or...

Page 2: ...2...

Page 3: ...nd Inspection 9 3 Functionality 9 4 Technical Specifications 10 5 Installation 11 16 5 1 SPS Connection 12 13 5 2 Power Supply Connection 14 5 3 Possible Connection Scenarios 15 16 6 On Off Control 16...

Page 4: ...azards DANGER This symbol indicates a direct hazard to the life and health of persons WARNING This symbol indicates a potential hazard to the life and health of persons CAUTION This symbol indicates a...

Page 5: ...gh intensity UV LED emitting devices for industrial applications To achieve short hardening times of the UV hardened materials intense UV radiation is necessary The standard CEI IEC 62471 describes th...

Page 6: ...d in IEC 62471 Risk free means that based on this standard there is no health hazard through irradiation Risk Group 1 Low risk Does not pose an irradiation hazard under normal performance and use Risk...

Page 7: ...in a distance 1 5 meters from the light source in order to protect eyes and skin Eye protection must be provided for work in the area within a distance of 1 5 to 3 meters from the point of the LED whe...

Page 8: ...subject to the EU Guidelines of the Chemicals Directive REACH Furthermore with regard to the planned candidate list of substances of very high concern SVHC issued on October 10 2008 Nordson EFD decla...

Page 9: ...e UV intensity correlates to that of a mercury vapor lamp with frequent electrical power consumption The BlueCure lamps are comprised of closely arranged semi conductor light emitting diodes that are...

Page 10: ...POWER AC 48V 32 0A http www meanwell com search rsp 1500 rsp 1500 spec pdf RSP 1500 48 Operational temperature 10 C to 40 C Humidity maximum of 80 rel humidity non condensing at 30 C Area of use Below...

Page 11: ...if it is mounted or integrated in a system using the fastening threads The lamp is connected to the liquid cooling system using the appropriate connections and its functionality and seals are checked...

Page 12: ...regarding the use of the output under 7 Intensity of the Radiation must also be complied with 6 Output 5 V DC 5 V DC The reference voltage is only intended for the operation of the lamp Improper use...

Page 13: ...utputs Pin 5 and 11 are not short circuit proof and may carry a maximum of 5 mA If multiple light sources are used together simultaneously the following pins can be looped through Pin 2 Input amp outp...

Page 14: ...in or disconnect the plug while under voltage For this purpose turn the power supply off first V V PE V V Pin Function Signal Level Remark V Input voltage 47 to 49 V DC 48 V DC input to the power sup...

Page 15: ...ensity from 20 to 100 No monitoring of errors and temperature Temperature monitoring via an external voltmeter No emergency shut off functionality S1 On off lamp T1 Power supply S1 On off lamp V1 exte...

Page 16: ...prevent heat from building Even if the surface of the lamp does not heat up high temperatures may develop in the area surrounding the lamp e g every material in the direct proximity for which there is...

Page 17: ...on Because the coolant extensively cools the cooling element of the lamp in certain operating conditions for expelling heat condensation may form in the lamp behind the glass of the light emitting wi...

Page 18: ...r cleaning the lamps 1 Run a solution consisting of vinegar and decalcified water Mixing ratio 1 1 n weight through the lamp for 15 minutes 2 In the next step run a pure vinegar solution through in th...

Page 19: ...ergency shut off functionality Bridge between pin 7 and grounding pin 14 Lamp output Bridge between pin 2 and pin 6 SLM error Check the wiring of the DB15 connection see 5 1 SPS Connection for this If...

Page 20: ...20 A Appendix A 1 Drawing of the BLUE CURE FL 8 0W 125X20 WC 395...

Page 21: ...21...

Page 22: ...Y Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship but not against damage caused by misuse abrasion corrosion negligence accide...