Nordmann Engineering FAN4 N L 32 W Installation And Operating Instructions Manual Download Page 10

10

3.5 Lieferumfang

FAN4 N l 5 W J

FAN4 N l 8 W J

Wandhalterung 285 mm

schrauben/Dübel-set

Ausblasstutzen ø22/ø45, l=175

Verbindungsstück ø45

schlauchklemmen-set

Kondensatschlauch-set

Kabelverschraubung M16x1.5

Kabeltülle ø22

Wall support 285 mm

set with screws and dowel

outlet adapter ø22/ø45, l=175

connecting piece ø45

set with hose clips

condensate hose set

cable gland M16x1.5

cable grommet ø22

support mural 285 mm

set avec vis et chevilles

Adaptateur de sortie ø22/ø45, l=175

Raccord ø45

set avec colliers de tuyaux

set tuyau de condensat

presse-étoupe M16x1.5

passe-câble ø22

FAN4 N l 15 W J

Wandhalterung 340 mm

schrauben/Dübel-set

Ausblasstutzen ø35/ø45, l=195

Verbindungsstück ø45

schlauchklemmen-set

Kondensatschlauch-set

Kabelverschraubung M16x1.5

Kabeltülle ø22

Wall support 340 mm

set with screws and dowel

outlet adapter ø35/ø45, l=195

connecting piece ø45

set with hose clips

condensate hose set

cable gland M16x1.5

cable grommet ø22

support mural 340 mm

set avec vis et chevilles

Adaptateur de sortie ø35/ø45, l=195

Raccord ø45

set avec colliers de tuyaux

set tuyau de condensat

presse-étoupe M16x1.5

passe-câble ø22

FAN4 N l 23 W J

Wandhalterung 340 mm

schrauben/Dübel-set

Ausblasstutzen ø35/ø45, l=170

Verbindungsstück ø45

schlauchklemmen-set

Kondensatschlauch-set

Kabelverschraubung M16x1.5

Kabeltülle ø22

Wall support 340 mm

set with screws and dowel

outlet adapter ø35/ø45, l=170

connecting piece ø45

set with hose clips

condensate hose set

cable gland M16x1.5

cable grommet ø22

support mural 340 mm

set avec vis et chevilles

Adaptateur de sortie ø35/ø45, l=170

Raccord ø45

set avec colliers de tuyaux

set tuyau de condensat

presse-étoupe M16x1.5

passe-câble ø22

FAN4 N l 32 W

Wandhalterung 340 mm

schrauben/Dübel-set

2 Ausblasstutzen ø35/ø45, l=170

2 Verbindungsstücke ø45

schlauchklemmen-set

Kondensatschlauch-set

2 Kabelverschraubungen M16x1.5

Kabeltülle ø22

Y-Verbindungsstück DsV 345 **

Wall support 340 mm

set with screws and dowel

2 outlet adapters ø35/ø45, l=170

2 connecting pieces ø45

set with hose clips

condensate hose set

2 cable glands M16x1.5

cable grommet ø22

Y connection piece DsV 345 **

support mural 340 mm

set avec vis et chevilles

2 Adaptateurs de sortie ø35/ø45, l=170

2 Raccords ø45

set avec colliers de tuyaux

set tuyau de condensat

2 presse-étoupes M16x1.5

passe-câble ø22

connecteur Y DsV 345 **

FAN4 N l 5 D J

FAN4 N l 8 D J

schrauben-set

Ausblasstutzen ø22/ø45, l=175

schlauchklemmen-set

Kondensatschlauch-set

Kabelverschraubung M16x1.5

Kabeltülle ø22

Adeckblende

set with screws

outlet adapter ø22/ø45, l=175

set with hose clips

condensate hose set

cable gland M16x1.5

cable grommet ø22

covering frame

set avec vis

Adaptateur de sortie ø22/ø45, l=175

set avec colliers de tuyaux

set tuyau de condensat

presse-étoupe M16x1.5

passe-câble ø22

cadre de couverture

FAN4 N l 15 D J

schrauben-set

Ausblasstutzen ø35/ø45, l=195

schlauchklemmen-set

Kondensatschlauch-set

Kabelverschraubung M16x1.5

Kabeltülle ø22

Adeckblende

set with screws

outlet adapter ø35/ø45, l=195

set with hose clips

condensate hose set

cable gland M16x1.5

cable grommet ø22

covering frame

set avec vis

Adaptateur de sortie ø35/ø45, l=195

set avec colliers de tuyaux

set tuyau de condensat

presse-étoupe M16x1.5

passe-câble ø22

cadre de couverture

3.5 Delivery

3.5 Livraison

3.4 Einsatzzweck

Die Ventilationsgeräte FAN4 dienen in Ver-

bindung mit den Dampfluftbefeuchtern Nord-

mann Es4 und Nordmann At4 zur direkten 

Raumluftbefeuchtung. Die Ven tilationsgeräte 

werden vorzugsweise einge setzt, wenn nur ein 

Raum zu befeuchten ist, wenn keine lüftungs- 

oder Klimaanlage vorhanden ist, wenn der 

Befeuchter nachträglich eingebaut wird oder 

für spezielle Befeuchtungsanwendungen.

3.4 Application

the FAN4 fan units are used in association with 

the Nordmann Es4 and Nordmann At4 steam 

air humidifiers for direct room air humidifica-

tion. The fan unit is chiefly used when only 

one room is to be humidified, when there is no 

ventilation or air-conditioning plant installed, 

when the humidifier has been subsequently 

installed, or for special humidity applications.

3.4  But d’utilisation

Combinés avec les humidificateurs à vapeur 

Nordmann Es4 et Nordmann At4, les appa-

reils de ventilation FAN4 sont destinées à 

l’humidi fication directe de locaux. Ces appa-

reils de ventilation s’utilisent de préfé ren ce 

lorsqu’il s’agit d’humidifier un seul local, en 

l’absence d’installation de ventilation ou de 

climatisation, lorsque l’humidificateur est ins-

tallé ultérieurement ou pour des applications 

d’humidi fi cation particuliers.

Summary of Contents for FAN4 N L 32 W

Page 1: ...E E R I N G Ventilationsger te Fan units Appareils de ventilation Nordmann FAN4 2569915 DE EN FR 1210 Montage und Betriebsanleitung Installation and Operating Instructions Instructions d installation...

Page 2: ......

Page 3: ...ing the steam air humidifier 14 4 3 Mounting 17 4 3 1 Mounting the fan units FAN4 N L D on the steam air humidifier Nordmann AT4 5 23 kg h 17 4 3 2 Mounting the fan unit FAN4 N L W on the wall 18 4 4...

Page 4: ...ywill beglad to assist you 1 2 Notes on the installation and operating instructions Limitation The subject of these installation and oper ating instructions are the fan units FAN4 in their different v...

Page 5: ...Veuillez conserver les pr sentes instructions d installationetd exploitationenunendroits r port e de main Remettre cette documenta tion un ventuel nouveau d tenteur En cas de perte de la documentatio...

Page 6: ...s curit du travail et la pr ven tion des accidents Cet appareil n est pas destin tre utili s par des personnes y compris enfants avec d ficiences physiques sensorielles ou mentales et ou sans exp rie...

Page 7: ...er If it is suspected that safe operation is no longer possible then the steam humidi fier and the fan unit should immediately be shut down and secured against accidental power up This can be the case...

Page 8: ...nn AT4 Nordmann ES4 5 8 kg h 1x 15 23 kg h 1x 32 kg h 1x Nordmann AT4 5 8 kg h 1x 15 23 kg h 1x 32 kg h 1x 46 kg h 2x 64 kg h 2x D Montage auf Dampf Luftbefeuchter Mounting on steam air humidifier Mon...

Page 9: ...e see figure above 1 Raccordement de vapeur 2 Raccordement de condensat 3 Cadre frontal uniquement FAN4 N L D J 4 Distributeur de vapeur 5 Couvercle d appareil 6 Bo te filtre 7 Passe c ble 8 Condenseu...

Page 10: ...is et chevilles 2 Adaptateurs de sortie 35 45 L 170 2 Raccords 45 Set avec colliers de tuyaux Set tuyau de condensat 2 Presse toupes M16x1 5 Passe c ble 22 Connecteur Y DSV 345 FAN4 N L 5 D J FAN4 N L...

Page 11: ...J Schrauben Set Ausblasstutzen 35 45 L 170 Schlauchklemmen Set Kondensatschlauch Set Kabelverschraubung M16x1 5 Kabelt lle 22 Adeckblende Set with screws Outlet adapter 35 45 L 170 Set with hose clip...

Page 12: ...va peur puisse se diffuser librement et pour viter qu il ne se condense des obstacles plafonds som miers piliers etc Nota les distances minimales figurant dans la table correspondante ont pour r f ren...

Page 13: ...ize the room height etc mustbetakenintoconsiderationbesides observing the minimum distances for the fan units FAN4 If you have questions concerning the direct room humidification please contact your N...

Page 14: ...in cup C Nordmann ES4 lead siphon hose down on the back side of the steam cylinder then push hose B3 into the appropriate opening of the base plate D Nordmann ES4 4 Steam humidifiers with one steam ou...

Page 15: ...g h 22 mm 45 mm 22 mm 14 10 mm A B2 B3 C B1 E 14 10 mm 35 mm 45 mm 35 mm A B2 B3 C B1 E 23 32 kg h 46 64 kg h 14 10 mm 35 mm 45 mm 35 mm A B2 B3 C B1 E 14 10 mm 35 mm 45 mm 35 mm A B2 B3 C B1 E 35 mm...

Page 16: ...16 Nordmann ES4 5 8 kg h 15 kg h 22 mm 45 mm 22 mm 14 10 mm A B3 D B1 B2 E 35 mm 45 mm 35 mm 14 10 mm A B3 D B1 B2 E 23 32 kg h 35 mm 45 mm 35 mm 14 10 mm A B3 D B1 B2 E...

Page 17: ...nt covers of the steam air humidifier 2 Break off the prepunched hole on top of thecontrolbox thenmountcablegrommet A 3 Remove front panel C on the bottom of the fan unit 4 Insert supply cable B into...

Page 18: ...0 mm 10x48 mm M6x6 A Anschlusskabel von oben oder unten ber die Kabelt lle imLieferumfangenthalten odereineKabelverschraubung in den Dampf Luftbefeuchter f hren Insert supply cable from the top or the...

Page 19: ...19 Nordmann AT4 46 kg h 64 kg h...

Page 20: ...nt au r seau lectrique avant l ach vement de l installation 4 4 Electrical installation The power supply is connected to the control voltage supply of the steam air humidifier in ac cordance with the...

Page 21: ...ongerbeing produced theventilatorswitchesoffautomati cally after a nominal overrun period 6 Maintenance Basically the fan units FAN4 do not require anymaintenance Iftheunitsand orthebuiltin filters sh...

Page 22: ...e vacuation 8 1 Mise hors service Si l appareil de ventilation FAN4 doit tre remplac ou si le syst me d humidification n est plus utilis proc dez comme suit 1 Mettre l humidificateur vapeur et l ap pa...

Page 23: ...Hz Nennstrom Nominal current Courant nominal 310 mA Leistungsaufnahme Power consumption Puissance 70 W Luftf rdermenge Air delivery D bit d air 510 m3 h Schalldruckpegel Sound pressure level Niveau de...

Page 24: ...10 36 255 220 468 391 280 45 38 5 9 2 Abmessungen Gewichte FAN4 N L D J AT4 5 8 kg h Masse in mm Dimensions in mm Dimensions en mm Gewicht Weight Poids 10 2 kg FAN4 N L D J AT4 15 23 kg h Masse in mm...

Page 25: ...25 FAN4 N L 32 W Masse in mm Dimensions in mm Dimensions en mm Gewicht Weight Poids 10 2 kg 26 334 55 170 115 103 155 31 40 69 104 104 260 45 10 36 255 13 468 280...

Page 26: ......

Page 27: ...Nordmann Engineering Ltd Printed in Switzerland Technische nderungen vorbehalten Technical data subject to modification Sous r serve de modifications techniques...

Page 28: ...E N G I N E E R I Dampfluftbefeuchter econ Reg No 40002 2 Manufacturer Nordmann Engineering Ltd Talstrasse 35 37 8808 Pf ffikon Switzerland Ph 41 55 416 66 06 Fax 41 55 416 62 46 www nordmann enginee...

Reviews: