memorizes the last set value and the normal display is
restored.
The temperature range is set from a minimum to a maximum,
according to the following values:
Positive temperature models
• “MIN“ setting = 0
℃
• “MAX“ setting = + 10
℃
Negative temperature models
• “MIN“ setting = – 2
℃
• “MAX“ setting = + 8
℃
Low temperature - freezer models (fully insulated door)
• “MIN“ setting = – 24
℃
• “MAX“ setting = – 15
℃
Low temperature - freezer models (glass door)
• “MIN“ setting = – 22
℃
• “MAX“ setting = – 15
℃
Fish models
• “MIN“ setting = – 7
℃
• “MAX“ setting = + 6
℃
I.2
Digital thermostat signalling icons
The digital thermostat has the following signalling icons:
lit up
This icon indicates compressor
activation.
lit up
This icon indicates the manual defrost
function in progress.
lit up
This icon indicates activation of com-
partment fans (if present) and/or
condenser.
lit up
This icon indicates that a temperature
alarm has occurred during appliance
operation.
lit up
This icon indicates that a service alarm
has occurred during appliance
operation.
I.3
Signalling and alarms
I.3.1
Service alarms and signalling for models 0
℃
℃
/+10
℃
℃
and freezer models
The alarm is signalled by lighting up of the icon
. Alarm
signalling is also indicated by the alarm code appearing on the
display.
Example: Alarm signalling due to a faulty probe (compartment
probe) appears directly on the instrument display with the
message “E0“ and “rE“ flashing alternately (refer to position 1
of the alarms table).
When the alarm condition ceases, the alarm goes off.
Otherwise, contact the Customer Care Service.
I.3.2
Service alarms and signalling for models -2
℃
℃
/
+8
℃
℃
and fish models
The alarm is signalled by lighting up of the Icon
.
Alarm signalling is also indicated by the alarm code appearing
on the display.
Example: Alarm signalling due to a faulty probe (compartment
probe) appears directly on the instrument display with the
message “E0“ and “rE“ flashing alternately (refer to position 1
of the alarms table).
Alarm signalling due to a faulty evaporator sensor (evaporator
sensor) appears directly on the instrument display with the
indication “E1“ flashing (refer to position 2 of the alarms table).
I.3.3
Temperature alarms and signalling (common to
all appliances)
The alarm is signalled by lighting up of the icon
. Alarm
signalling is also indicated by the alarm code appearing on the
display.
Temperature alarm signalling, regarding the thermostatting
probe, appears directly on the instrument display with the
indication “HI“ (max. temperature alarm) and “LO“ (min.
temperature alarm).
I.3.4
Door open alarms and signalling for high
humidity, fish models
When the door is opened the display starts flashing together
with the icon
. If the door remains open for more than a few
minutes, the display shows the message dor (accompanied by
a beep), alternating with the temperature value. The alarm is
deactivated when the door is closed.
I.4
Defrost
•
Automatic defrost (excluding freezer models)
The appliance has an automatic defrost function. This
function is signalled by lighting up of the “DEFROST“ icon
.
The defrost water is run into a tray and automatically
evaporated.
•
Manual defrost activation
Keep the “DOWN“ button pressed for at least 5 seconds to
start a manual defrost cycle.
This function is signalled by lighting up of the “DEFROST“
icon
.
If defrost conditions do not exist, the display shows the
message “dFb“, indicating that the operation will not be
carried out (
only for - 2
℃
℃
/+8
℃
℃
and fish models
).
Defrost can be stopped manually by pressing the “DOWN“
button for a few seconds:
the display shows the message “dFb“. Defrost cannot be
activated in the programming stage.
I.5
Defrost
These appliances are equipped with a device that provides for
automatic defrosting. The defrost water is run into a tray
located above the compressor and made to evaporate
automatically.
I.6
Defrost for freezer models (with
evaporating grilles)
Manual defrost must be carried out for these models when the
layer of frost is more than 5 mm thick.
To defrost, carry out these instructions:
• remove any load present in the compartment and put it in
another available freezer unit;
• position the water tray (supplied) on the bottom of the
compartment;
• switch off the appliance with the “ON/OFF“ button;
• unplug the appliance;
• open the door and wait until all the ice on the evaporating
grilles has melted and the water has run into the tray
• empty the tray (several times if necessary);
29
Summary of Contents for 402729447
Page 1: ...Bedienungsanweisung Umluft Gewerbek hlschrank KU 400 G W Art 402729447 2019 12...
Page 7: ...EI Netzkabel 7...
Page 10: ...K ENTSORGUNG DES GER TS 33 K 1 Entsorgung 33 K 2 Zerlegen des Ger ts 33 10...
Page 34: ...Installation and Operating Manual Vertical Refrigerators KU 400 G W Art 402729447 2019 12...
Page 40: ...EI Power cable 7...