F.2
The customer's responsibilities
The tasks and works required of the Customer are:
• provide an earthed power socket of suitable capacity for the
input specified on the dataplate;
• provide a high sensitivity manual-reset differential thermal-
magnetic switch. For information regarding the electrical
connection, refer to
• check the flatness of the surface on which the machine is
placed.
F.3
Positioning
Install the appliance, taking all the safety precautions required
for this type of operation, also respecting the relevant fire-
prevention instructions.
Install the appliance in a ventilated place, away from heat
sources such as radiators or air conditioning systems, to allow
correct cooling of the refrigerating unit components.
Never cover the condenser, even temporarily, as this can
compromise proper operation of the condenser and therefore
the appliance.
If the machine is installed in a place where there are corrosive
substances (chlorine, etc.), it is advisable to go over all the
stainless steel surfaces with a rag soaked in paraffin oil to
create a protective film.
CAUTION
When positioning to take into account the
following distances:
• at least 500 mm from the top;
• 50 mm from the sides and back.
Arranging the machine:
• position the machine in the required place;
• adjust the height and levelling with the adjustment feet, also
checking correct door closing
CAUTION
The appliance must be levelled, otherwise
its operation could be affected.
F.4
Fitting anti-tipping cables
To fit, proceed as follows:
1. undo the two Phillips screws positioned on the top of the
appliance as shown in the figure;
2. remove the cables from their packing;
3. join a slot of the cable to the screw;
min. 500 mm
min.
50
mm
min.
50
mm
25
Summary of Contents for 402729447
Page 1: ...Bedienungsanweisung Umluft Gewerbek hlschrank KU 400 G W Art 402729447 2019 12...
Page 7: ...EI Netzkabel 7...
Page 10: ...K ENTSORGUNG DES GER TS 33 K 1 Entsorgung 33 K 2 Zerlegen des Ger ts 33 10...
Page 34: ...Installation and Operating Manual Vertical Refrigerators KU 400 G W Art 402729447 2019 12...
Page 40: ...EI Power cable 7...