Residual risk
Description of hazardous situation
Slipping or falling
The operator can slip due to water or dirt on the
floor
Burns/abrasions (e.g. heating
elements, cold pan, cooling
circuit plates and pipes)
The operator deliberately or unintentionally
touches some components inside the machine
without using protective gloves.
Electrocution
Contact with live parts during maintenance
operations carried out with the electrical panel
powered
Falling from above
The operator intervenes on the machine using
unsuitable systems to access the upper part (e.g.
rung ladders, or climbs on it)
Crushing or injury
The specialised personnel may not correctly fix the
control panel when accessing the technical
compartment. The panel could close suddenly.
Tipping of loads
When handling the machine or the packing
containing it, using unsuitable lifting systems or
accessories or with the unbalanced load
Chemical (refrigerant gas)
Inhalation of refrigerant gas. Therefore always
refer to the appliance labels
IMPORTANT
In case of a significant anomaly (e.g. short circuits, wires coming out of the
terminal block, motor breakdowns, worn electrical cable sheathing, etc.) the
operator must immediately deactivate the machine.
A.5
Technical data
Materials and fluids used
• R290 and R600a gas are potentially flammable and explosive! Take every possible
precaution to prevent any risk linked to the nature of this gas during any routine and/or
extraordinary operation carried out on the appliance.
Performance
Equivalent sound pressure level Leq dB(A)
1
<70
1. The noise emission values have been obtained according to EN ISO 11204. The value could increase
depending on the workplace where measured.
Climatic Class
The climatic class given on the data plate refers to the following values:
•
High humidity, fish and fully insulated door refrigerated models
:
Climatic Class 5:
– 43
℃
(IEC/EN 60335-2-89)
Climatic Class 4 (not given in the data plate):
– 30
℃
room with 55% relative humidity (EN 16825/EN ISO 22041)
•
Glass door refrigerated model:
Climatic Class 5:
– 43
℃
(IEC/EN 60335-2-89)
Climatic Class 3 (not given in the data plate):
15
Summary of Contents for 402729447
Page 1: ...Bedienungsanweisung Umluft Gewerbek hlschrank KU 400 G W Art 402729447 2019 12...
Page 7: ...EI Netzkabel 7...
Page 10: ...K ENTSORGUNG DES GER TS 33 K 1 Entsorgung 33 K 2 Zerlegen des Ger ts 33 10...
Page 34: ...Installation and Operating Manual Vertical Refrigerators KU 400 G W Art 402729447 2019 12...
Page 40: ...EI Power cable 7...