1 General
BU 0505 EN-3021
11
Feature
SK …
50xE
51xE
511E
520E
53xE
54xE
Additional
options
Operating manual
BU 0500
BU
0505
Safe pulse block (STO / SS1)*
x
x
x
x
2 x CANbus/CANopen interfaces via RJ45
plug
x
x
x
x
RS485 interface additionally via terminals
x
x
x
Speed feedback via incremental encoder
input
x
x
x
Integrated “POSICON” positioning control
x
x
CANopen absolute encoder evaluation
x
x
PLC / SPS – functionality
x
x
x
Universal encoder interface
(SSI, BISS, Hiperface, EnDat and SIN/COS)
x
Operation of PM synchronous motors
(
P
ermanent
M
agnet
S
ynchronous
M
otors)
x
x
x
x
x
x
Number of digital inputs / outputs**
5 / 0
5 / 0
5 / 0
7 / 2
7 / 2
5 / 3 6 / 2
7 / 1
Additional potential-isolated PTC input***
x
Number of analog inputs / outputs
2 / 1
2 / 1
2 / 1
2 / 1
2 / 1
2 / 1
Number of relay messages
2
2
2
2
2
2
* not with 115 V devices
** SK 54xE: 2 I/Os can be variably parameterised as inputs or outputs
*** alternative "thermistor" function on digital input 5 possible (above size 5 an additional thermistor input is available as
standard)
Table 2: Overview of SK 500E performance grading features
Pos: 21 /Anleitungen/Elektronik/FU und Starter/1. Allgemeines/Überblick -2- Abweichende Hardwareeigenschaften [SK 5xxE] @ 1\mod_1340695009508_388.docx @ 28170 @ @ 1
Differing hardware features
Version
Description
SK 5xxE
-
…
-
CP
compared with SK 5xxE
•
ColdPlate or external heat sink
SK 5x5E
compared with SK 5x0E
•
External 24V supply voltage. Communication with the frequency inverter is
possible even without a power connection
For size 5 and above in
comparison with sizes 1 –
4 (> 4 kW, 230V or
> 11 kW, 400V)
•
Additional, separately mounted PTC input (potential isolated)
•
External 24V supply voltage with automatic switchover to the internal 24V low
voltage generator on failure of the external control voltage.
•
Processing of both bipolar and analog signals
•
2 x CANbus/CANopen interfaces via RJ45 plug as standard
Table 3: Overview of differing hardware features
Pos: 22 /Anleitungen/Elektronik/FU und Starter/1. AllgemeinesSK 5xxE mit bzw. ohne integriertem Netzfilter @ 6\mod_1421331128135_388.docx @ 199338 @ 23335 @ 1
Summary of Contents for NORDAC PRO SK 5 E-111 CP Series
Page 1: ...EN BU 0505 SK 54xE Users Manual for Frequency Inverters...
Page 5: ...Publisher BU 0505 EN 3021 5...
Page 214: ...SK 54xE Users Manual for Frequency Inverters 214 BU 0505 EN 3021...
Page 215: ...Key word index BU 0505 EN 3021 215...
Page 216: ...SK 54xE Users Manual for Frequency Inverters 216 BU 0505 EN 3021...
Page 217: ......
Page 218: ...6075052 3021...