4 Commissioning
BU 0505 EN-3021
87
2. CFC closed-loop mode (P300, setting "1")
In contrast to the "0" setting "VFC open-loop mode" this is a form of control with current controlled
flux orientation (Current Flux Control). For this operating mode, which for ASMs is functionally
identical to the previously used designation "servo control", use of an encoder is essential. The
precise speed behaviour of the motor is detected and included in the calculation for control of the
motor. Determination of the position of the rotor is also possible through the use of the encoder,
whereby the initial value of the rotor position must also be determined for the operation of a PMSM.
This enables even more precise and rapid control of the drive unit.
This operating mode provides the best possible results for the control behaviour of both ASMs and
PMSMs and is especially suitable for lifting equipment applications or applications with
requirements for the hi
ghest possible dynamic behaviour (ramp times ≥
0,05 sec). The greatest
advantage of this operating mode is gained in combination with an IE4 motor (energy efficiency,
dynamics, precision).
Pos: 115.5 /Anleitungen/Elektronik/FU und Starter/4. Inbetriebnahme/Inbetriebnahme Betriebsarten Motorregler (P300) [SK 1x0E, SK 2xxE]/Erläuterung der Betriebsarten (P300)_03 [SK 1x0E, SK 2xxE, SK 5xxE] @ 8\mod_1441288721267_388.docx @ 239804 @ @ 1
3. CFC open-loop –mode (P300, setting "2")
CFC mode is also possible with the open-loop method, i.e. in operation without an encoder. Here,
the speed and position detection are determined by "observation" of measurements and setting
values. Precise setting of the current and speed controller is also essential for this operating mode.
This mode is especially suitable for applications with higher demands for dynamics in comparison
with VFC control (ramp times ≥
0.25 s) and e.g. also for pump applications with high starting
torques).
Pos: 115.6 /Anleitungen/Elektronik/FU und Starter/4. Inbetriebnahme/Auswahl Motorregelverfahren/Parameterübersicht Reglereinstellung [SK 2xxE, SK 5xxE] @ 6\mod_1421067020960_388.docx @ 198341 @ 3 @ 1
4.2.2 Overview of control parameter settings
The following provides an overview of all parameters which are of importance, depending on the
selected operating mode. Among other things, a distinction is made between "relevant" and
"important", which provides an indication of the required precision of the particular parameter setting.
However, in principle, the more precisely the setting is made, the more exact the control, so that
higher values for dynamics and precision are possible for the operation of the drive unit. A detailed
description of these parameters can be found in Section 5 "Parameters".
"Ø" =
Parameter has no significance
"-" =
Leave the parameter in the factory setting
"√"
=
Setting of the parameter is relevant
"!" =
Setting of the parameter is important
Group
Parameter
Operating mode
VFC open-loop
CFC open-loop
CFC closed-loop
ASMs
PMSMs
ASMs
PMSMs
ASMs
PMSMs
Mo
to
r d
a
ta
P201 … P209
√
√
√
√
√
√
P208
!
!
!
!
!
!
P210
√
1)
√
√
√
Ø
Ø
P211, P212
-
2)
-
-
-
-
-
P215, P216
-
1)
-
-
-
-
-
P217
√
√
√
√
Ø
Ø
P220
√
√
√
√
√
√
P240
-
√
-
√
-
√
P241
-
√
-
√
-
√
P243
-
√
-
√
-
√
P244
-
√
-
√
-
√
P246
-
√
-
√
-
√
P245, 247
-
√
Ø
Ø
Ø
Ø
Summary of Contents for NORDAC PRO SK 5 E-111 CP Series
Page 1: ...EN BU 0505 SK 54xE Users Manual for Frequency Inverters...
Page 5: ...Publisher BU 0505 EN 3021 5...
Page 214: ...SK 54xE Users Manual for Frequency Inverters 214 BU 0505 EN 3021...
Page 215: ...Key word index BU 0505 EN 3021 215...
Page 216: ...SK 54xE Users Manual for Frequency Inverters 216 BU 0505 EN 3021...
Page 217: ......
Page 218: ...6075052 3021...