P708
State of digital in.
(Status of digital inputs)
000000000 ...
111111111 (binary)
(Display with *SK-TU3-
PAR)
or
0000 ... 01FF (hex)
(Display with *SK-TU3-
CTR *SK-CSX-0)
Displays the status of the digital inputs in binary/hexadecimal code. This display can be used to
check the input signals.
Bit 0 =
Digital input 1
Bit 1 =
Digital input 2
Bit 2 =
Digital input 3
Bit 3 =
Digital input 4
Bit 4 =
Digital input 5
Bit 5 =
Digital input 6
(SK
520E and
above)
Bit 6 =
Digital input 7
(SK
520E and
above)
Bit 7 =
Analog input 1
(digital function)
Bit 8 =
Analog input 2
(digital
function)
Bit 9 =
Digital input 8
(SK
540E and above)
Bit 10 =
Digital input 1/1 IOE
(SK
540E and above)
Bit 11 =
Digital input 2/1 IOE
(SK
540E and above)
Bit 12 =
Digital input 3/1 IOE
(SK
540E and above)
Bit 13 =
Digital input 4/1 IOE
(SK
540E and above)
Bit 14 =
Digital input 1/2 IOE
(SK
540E and above)
Bit 15 =
Digital input 2/2 IOE
(SK
540E and above)
Bits 11-8
Bits 7-4
Bits 3-0
Minimum value
0000
0
0000
0
0000
0
Binary
hex
Maximum value
0001
1
1111
F
1111
F
Binary
hex
ControlBox:
the binary Bits are converted into a hexadecimal value and displayed.
ParameterBox:
the Bits are displayed increasing from right to left (binary).
Pos: 387 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P709 – Spannung Analogeingänge [SK 54xE] @ 0\mod_1328172336181_388.docx @ 12548 @ @ 1
P709
[-01]
...
[-10]
Analog input voltage
(Voltage of analog inputs)
-10.00 ... 10.00 V
Displays the measured analog input value.
[-01] = Analog input 1
: analog input 1, integrated into the FI
[-02] = Analog input 2
: analog input 2, integrated into the FI
[-03] = External analog input 1
,
"External analog input 1"
: Analog input 1 of the first IO extension
[-04] = External analog input 2
,
"External analog input 2"
: Analog input 2 of the first IO
extension
[-05] = External Analog input 1, 2nd IOE,
"External analog input 1 of the 2nd IOE"
: Analog input
1 of the second IO extension
[-06] = External Analog input 2, 2nd IOE, "E
xternal analog input 2 of the 2nd IOE"
: Analog input
2 of the second IO extension
[-07] = Analog function, Dig2
,
"Analog function of digital input 2"
: Analog function of digital input
2 integrated into the FI.
[-08] = Analog function, Dig3
,
"Analog function of digital input 3"
: Analog function of digital input
3 integrated into the FI.
[-09] = Encoder track A
: Monitoring of the input signal of track A of an incremental encoder
(Terminal X6:51/52)
[-10] = Encoder track B
Monitoring of the input signal of track B of an incremental encoder
(Terminal X6:53/54)
NOTE:
The voltage difference between tracks A and B of and incremental encoder can be
measured with the aid of parameter P709 [-09] and [-10]. If the incremental encoder is
rotated the value of both tracks must jump between -0.8V and 0.8V. For Hiperface
encoders the voltage ranges from -0.5V...0.5V. If the voltage only jumps between 0 and
0.8V the relevant rack is faulty. It may be possible to determine the position with the
incremental encoder, but the interface is considerably more susceptible to faults. We
recommend replacement of the encoder!
Pos: 389 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P710 – Spannung Analogausgänge [SK 54xE] @ 0\mod_1328172483998_388.docx @ 12594 @ @ 1
Summary of Contents for NORDAC PRO SK 5 E-111 CP Series
Page 1: ...EN BU 0505 SK 54xE Users Manual for Frequency Inverters...
Page 5: ...Publisher BU 0505 EN 3021 5...
Page 214: ...SK 54xE Users Manual for Frequency Inverters 214 BU 0505 EN 3021...
Page 215: ...Key word index BU 0505 EN 3021 215...
Page 216: ...SK 54xE Users Manual for Frequency Inverters 216 BU 0505 EN 3021...
Page 217: ......
Page 218: ...6075052 3021...