29
9
Connecting the Sensors to the CANbus
1.
Fasten the 8-way coupler (E11) to the boom with cable ties. Connect cable C03 from the
valve module to the 8-way coupler.
2.
Connect the main lift sensor to the 8-way coupler using cable C04 and a 2-way coupler
(E12). Cable C04 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.
3.
Connect the sensor on the linear roll cylinder to the 8-way coupler using cable C04 and a
2-way coupler (E12).
4.
Attach a 3-way coupler (E10) to the boom at the inner sensor brackets. Connect two
cables (C05) to the 8-way coupler and route along the booms to the inner wing sensors.
Plug the sensor and the CANbus cable into the 3-way coupler.
5.
Connect cable C05 to the remaining connector on the 3-way coupler and route along the
boom to the outer wing sensors.
Figure 28: UC5 Module Locations and Cable Connections
6.
At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.
The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.
Ensure that all unused connectors are plugged with the plugs provided.