36
Press and hold the Check button. Continue holding while each
boom section is moved. The display will show an arrow. At
this time the boom will be in motion. When it is done the
display will instruct you to release the Check button. Do not
move the booms at this time.
Press and hold the Check button and continue holding it until
instructed to release it.
The system will now calibrate the hydraulics. All boom
sections will move.
If you accidentally release the button, select and hold the
Check button to resume.
The setup is now complete and the controller will return to
the main run screen.
12.3
Post-Calibration Check
1.
Put the system into Auto Mode by pressing the “A” button. The boom should level out.
Put the system back into Manual Mode by pressing the “M” button.
2.
Verify that the sensor heights are correct. Measure the distance from the lowest point of
the boom to the ground near each sensor
.
With the system in Manual Mode, select the Settings button
(wrench).
Select the Next button (right arrow).
Select the Next button (right arrow).