START-S7lT
operating guide
-16-
6
Managing of the REMOTE CONTROL DIP9 OFF
This receiver can manage standard codes from 12 till 64 bit and rolling codes HCS©. The first learned transmit
-
ter establish the code’s type taht the receiver has to manage, it means that the transmitter has to have the same
code’s type. Concerning the rolling codes it is possible to activate or disactivate the key’scontrol and the rolling
counter. with this function you can choose the security level of the receiver.
6.1
Cancellation of the memory
The control unit dispose of a button
P1
to cancel the memory of the remote controls.
To do this operation make as follow:
The outputs are deactivated, so no contacts available, the connected lights should be switched off.
This operation is possible only when the gate is closed.
1
Press and keep presse
the
button P
on the control board, led l1 will lit on
2
After 6 seconds the LED L1
will turned off and now you can release the
button P1
.
LED L1 will flash 4 times then it will flash regularly and it is ready to manage the fixed code
(1 regular flash see next chapter). The memory is cancelled.
1
Press and keep presse
the
button P
on the control board, led l1 will lit on.
2
In these 6 seconds press and release
button P
, LED L1 will flash one and it will lit on for 6 seconds.
3
In 6 seconds press and
release P1
again, LED L1 flashes twice and then it flashes constantly,
this memorize the rolling code remote controls.
The receiver of the START-S7LT can manage fixed and rolling code. The outputs should be deactivated, no contacts
available, lights turned off. This operation is possible only when the gate is closed
LED L1
in normal condition indicates the type of code you are managing
1 regular flash:
it will be managed compatible fixed code
2 regular flash:
it will be managed only rolling code remote like:
serie Smile, Smart”
In case you need to manage the compatible fixed code follow the passages 1 and 2 and wait until LED L1 will be
switched off. In this case the first memorized code determines they type of code which should be memorized. If you had
to memorize a 12bit remote control (for example dip switch) it will be memorized 12 bits of the same version
6.2
Activation of the codes