START-S7lT
operating guide
-20-
7.3
Use the input CLOSE for PARTIAL OPENING
1
Take the power supply and put
DIP9
in
ON.
The gate is
CloSed
2
Give power supply to the control unit. (led l1 is
turned off when the control board is programming)
The gate is
oPenInG
3
Press the CloSe command (everything connected
to input 16 or the 2nd channel of the compatible
remote control that has been learned)
The gate is
oPenInG
4
Press the CloSe command to stop the automation
at the desired point (end of partial opening).
The gate is
SlowInG down
5
let the time elapse during which the automation
must remain open.
This is the
automation
“PAUSE TIME”
6
Press CloSe command to start closing
The automation
starts in
CloSInG mode
7
wait for the automation to stop automatically
The gate is
CloSed
8
Put in
OFF
the
DIP9
to return in the standard
function. The signal light turned off and led l1 will
starts again.
end of the
memorization of the
working time
4
2
1
4
3
6
5
8
7
10
9
2
1
4
3
6
5
8
7
10
9
7.4
Go back to the INPUT CLOSE for CLOSE FUNCTION
1
Take the power supply and put
DIP9
in
ON.
2
Give power supply to the control unit.
(led l1 is turned off when the control board is programming)
3
Press and hold the CloSe command (everything connected to input 16 or the 2nd
channel of the compatible remote control that has been learned)
4
wait until the led1 starts blinking (about 5 seconds)
5
Release the button CloSe
6
Put in
OFF
the
DIP9
to return in the standard function. The signal light turned off and
led l1 will starts again.
4
2
1
4
3
6
5
8
7
10
9
2
1
4
3
6
5
8
7
10
9
In case you need to use the input CloSe for PARTIAl oPenInG, make as follow:
Summary of Contents for START-S7LT
Page 12: ......
Page 36: ......
Page 92: ...START S7LT Manual T cnico 21...
Page 118: ......
Page 120: ...REC S7 Cavetto per collegamento batteria 12V ricarica e soccorso...