START-S7lT
operating guide
-9-
4.9
Connection of the LIGHT
DIP 8 - ON
ON
CTS
2
1
4
3
6
5
8
7
10
9
12
11
4.11
Connection of the STOP
11 12 13 14 15 16 17 18
Connection of the
STOP
control
Push-button: stops and temporarily prevents all control
unit function until it is pressed again.
Switch: keeps the automation blocked until it is reset.
Connection of the safety devices requires the use of any push-
button or n.C. (normally closed) contact. when there are
several safety devices, they are connected in series.
If the input STOP is
not used bring DIP 1B
in ON
!
If you bring dIP8 in on you can connect
a signa light which will be lit on before
opening and two minutes after closing.
Signal light activated
with the second channel
of the remote control
10
6
7
8
5
10
11
12
9
14
15
16
13
18
17
GRoUP oF
lIGHT
Besides the second channel of the remo-
te control doesn’t close but it activate or
deactivate the signal light.
4.10 Connection of the ELECTRICAL LOCK
6
7
8
5
10
11
12
9
14
15
16
13
18
17
DIP 8 - OFF
ON
CTS
2
1
4
3
6
5
8
7
10
9
12
11
If you put dIP8 in oFF you can connect
an electric lock. If you install a signal light
(Courtesy light) it is not possible to con-
nect an electrical lock.