12/24 Vac/dc
1
Input for low tension: set up the JUMPeR J12
2
Motor
3
output for the connection of the MoToR
4
- 12/24 Vdc 5
output for the connection of the accessories: Absorption max 1.6 A
+ 12/24 Vdc 6
i.c. lamp
7
Isolated contact for lAMP
8
contact for elec.
lock / signal light
9
Isolated contact for eleC. loCK or SIGnAl lIGHT
10
Stop 11
Ingresso SToP
Photo Cl 12
Input photocell PHoTo: operating only when closing
olS 13
Input for open limit Switch
ClS 14
Input for Close limit Switch
Start 15
Input for START command: set up dIP 1 and dIP2
Close 16
Input CloSe command
Common 17
Common, services and securities
+ Antena 18
Positive pole antena
+ 5 Vdc 19
Power supply of the encoder
Sgn encoder 20
encoder signal
- 5 Vdc 21
Power supply of the encoder
START-S7lT
operating guide
-7-
4.3
Description of the electrical connections
We remind you that in
case some inputs are not
used, (STOP, FOTO) you
need to be deactivated
with DIPB as shown in the
Par 5.2
!
The LED L1 indicate the correct logic of the control board. It fl ashes each second and it indicates
that the micro-chip is activated and it is waiting for a command.
when the control board is powered, the led are lit on when the input is a closed contact.
normally the red led
STOP - PHOTO - OLS - CLS
are lit on
normally the green led in in the
START - CLOSE
are switched off
STOP PHOTO OLS CLS START CLOSE
4.4
Checking connections